Two-dimensional graphite-like carbon nitride nanosheets (g-C3N4 NSs) were hybridized with gold nanoparticles (Au NPs) to construct an electrochemiluminescence (ECL) immunosensor. The prepared Au NP-functionalized g-C3N4 NS nanohybrids (Au-g-C3N4 NHs) exhibit strong and stable cathodic ECL activity compared to g-C3N4 NSs due to the important roles of Au NPs in trapping and storing the electrons from the conduction band of g-C3N4 NSs, as well as preventing high energy electron-induced passivation of g-C3N4 NSs. On the basis of the improved ECL stability and ECL peak intensity of the Au-g-C3N4 NHs, a novel ECL immunosensor was developed to detect carcinoembryonic antigen (CEA) as a model target analyte. The ECL immunosensor has a sensitive response to CEA in a linear range of 0.02-80 ng mL(-1) with a detection limit of 6.8 pg mL(-1). Additionally, the proposed immunosensor shows high specificity, good reproducibility, and long-term stability.
This review overviews the recent development of nanomaterials for the application of electrochemical non-enzymatic glucose biosensors. The electrocatalytic mechanism and glucose sensing performance of a variety of nanostructured materials including metallic nanoparticles, metal oxides, metal complexes, alloys and carbon nanomaterials are discussed. The merits and shortfalls of each nanomaterial as electrocatalyst for non-enzymatic biosensing are evaluated and the prospects of non-enzymatic glucose biosensors are presented.
A novel one-dimensional hierarchically structured TiO(2) (1DHS TiO(2)) was synthesized by a solvothermal method using multiwalled carbon nanotubes (MWCNTs) as a template and evaluated for the immobilization of protein and biosensing applications. Characterization studies showed that the 1DHS TiO(2) possessed an anatase crystalline structure and a large surface area with narrow pore size distribution. Fast direct electron transfer was observed for glucose oxidase (GOx) immobilized on the 1DHS TiO(2), and excellent electrocatalytic performance for glucose detection can be obtained without a mediator. The glucose sensor based on the GOx/1DHS TiO(2)-modified electrode had a high sensitivity of 9.90 μA mM(-1) cm(-2) and a low detection limit of 1.29 μM. The fabricated biosensor displayed good selectivity and long-term stability, indicating that the novel structured TiO(2) is a promising material for the immobilization of biomolecules and the fabrication of third-generation biosensors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.