Purpose Force enhancement is the phenomenon of increased forces during (transient force enhancement; tFE) and after (residual force enhancement; rFE) eccentric muscle actions compared with fixed-end contractions. Although tFE and rFE have been observed at short and long muscle lengths, whether both are length-dependent remains unclear in vivo. Methods We determined maximal-effort vastus lateralis (VL) force-angle relationships of eleven healthy males and selected one knee joint angle at a short and long muscle lengths where VL produced approximately the same force (85% of maximum). We then examined tFE and rFE at these two lengths during and following the same amount of knee joint rotation. Results We found tFE at both short (11.7%, P = 0.017) and long (15.2%, P = 0.001) muscle lengths. rFE was only observed at the long (10.6%, P < 0.001; short: 1.3%, P = 0.439) muscle length. Ultrasound imaging revealed that VL muscle fascicle stretch magnitude was greater at long compared with short muscle lengths (mean difference: (tFE) 1.7 mm, (rFE) 1.9 mm, P ≤ 0.046), despite similar isometric VL forces across lengths (P ≥ 0.923). Greater fascicle stretch magnitude was likely to be due to greater preload forces at the long compared with short muscle length (P ≤ 0.001). Conclusion At a similar isometric VL force capacity, tFE was not muscle-length-dependent at the lengths we tested, whereas rFE was greater at longer muscle length. We speculate that the in vivo mechanical factors affecting tFE and rFE are different and that greater stretch of a passive component is likely contributing more to rFE at longer muscle lengths.
The clothing manufacturer Venex Life-Science tracks the strategy to enhance recovery process through implementing platinum harmonized technology (PHT) into their Venex® Regeneration Wear. The proposed mechanisms of the regeneration wear are an increase of parasympathetic activity and an increase of the temperature due far-infrared radiation. The purpose of this study was to investigate potential effects of Venex regeneration wear on the recovery of neuromuscular, systemic and subjective parameters following exercise. In a randomized, single-blinded cross-over design, 13 strength-trained male participants performed two exercise sessions in one day. After the first exercise session and for 3 nights following the exercise day participants wore the Venex regeneration wear or a placebo product. Measures of isometric maximum voluntary contraction (MVC), voluntary activation (VA) and potentiated twitch torque (PTT) of the knee extensors, as well as maximum jump height during the Counter-Movement and Drop Jump, creatinkinase (CK) and subjective parameters (perceived pain, recovery condition and sleep quality) were obtained before and after each exercise session and 24, 48, and 72 hours after the first exercise session. MVC, PTT, CK and jump parameters changed over time during the exercise day as well as on the following days, however, there were no significant differences between treatments. Subjective parameters showed strong effect sizes (i. e. Cohen’s d > 0.6) in favor for Venex but no significant differences between treatments. Based on these findings, it is concluded that wearing a platinum harmonized textile following exercise did not improve neuromuscular and systemic recovery in a trained male population to a statistical noticeable extent. However, the findings for the subjective parameters suggest some potential for enhanced recovery that requires further research.
Little is known about how muscle length affects residual force enhancement (rFE) in humans. We therefore investigated rFE at short, long, and very long muscle lengths within the human quadriceps and patellar tendon (PT) using conventional dynamometry with motion capture (rFETQ) and a new, non-invasive shear-wave tensiometry technique (rFEWS). Eleven healthy male participants performed submaximal (50% max.) EMG-matched fixed-end reference and stretch-hold contractions across these muscle lengths while muscle fascicle length changes of the vastus lateralis (VL) were captured using B-mode ultrasound. We found significant rFETQ at long (7±5%) and very long (12±8%), but not short (2±5%) muscle lengths, whereas rFEWS was only significant at the very long (38±27%), but not short (8±12%) or long (6±10%) muscle lengths. We also found significant relationships between VL fascicle length and rFETQ (r=0.63, p=.001) and rFEWS (r=0.52, p=.017), but relationships were not significant between VL fascicle stretch amplitude and rFETQ (r=0.33, p=.126) or rFEWS (r=0.29, p=.201). PT shear-wave speed-angle relationships did not agree with estimated PT force-angle relationships, which indicates that estimating PT loads from shear-wave tensiometry might be inaccurate. We conclude that increasing muscle length rather than stretch amplitude contributes more to rFE during submaximal voluntary contractions of the human quadriceps.
Torque production during maximal voluntary explosive contractions is considered to be a functionally more relevant neuromuscular measure than steady-state torque, but little is known about accelerated concentric contractions. This study investigated torque, muscle activity, and fascicle behavior during isometric and fast concentric contractions of quadriceps femoris. Ten participants performed maximal voluntary explosive isometric, isovelocity, and additional concentric knee extensions at angular accelerations ranging from 700 to 4000° s that resulted in an angular velocity of 300° s at 40° knee flexion. Concentric torque at 40° knee flexion was corrected for inertia, and the corresponding isometric torque was matched to the time when the target knee angle of 40° was reached during concentric contractions. Electromyography of quadriceps femoris and hamstrings and ultrasound of vastus lateralis were measured to determine muscle activity, fascicle length, and fascicle velocity (FV). The faster the acceleration, the more torque was produced during concentric contractions at 40° knee flexion, which was accompanied by a reduction in FV. In comparison with isometric conditions, concentric quadriceps muscle activity was increased and torque during accelerations ≥3000° s equaled the time-matched isometric torque. Our results provide novel evidence that acceleration influences torque production during maximal voluntary explosive concentric contractions. This is suggested to be due to series elasticity and reduced force depression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.