Purpose This study aimed to verify if the navigation system used in high tibial osteotomy (HTO) adds precision to the procedure regarding mechanical axis correction and prevention of tibial slope increases. Methods In this historically controlled study, patients with medial osteoarthrosis and genuvarum underwent HTO between 2004 and 2012; the first 20 were operated with the conventional technique, using pre-planning correction by the Dugdale method and 18 further patients were operated with the navigation system introduced in our hospital. Results The two groups were similar for pre-operative mechanical axis (mean 8.10±3.14 for the control and 6.60± 2.50 for the navigated group), pre-operative tibial slope (mean 8.95±3.47 versus 8.17±3.11, respectively) and Lyshom score (40.85±15.46 and 44.83±16.86). After surgery, the control group presented mean mechanical axis of 3.35±3.27, tibial slope of 13.75±3.75 and Lyshom score of 87.60±11.12. The navigated group showed a postoperative mechanical axis mean of 3.06±1.70, tibial slope of 10.11±0.18 and Lyshom score of 91.94±11.61. Conclusions The navigation system allowed a significantly better control of tibial slope. Patients operated with the navigation system had significantly better Lysholm scores.
Some viable alternatives to MRI have been suggested. For the lateral meniscus, anthropometric data are an alternative for width, and the Yoon method can be used to assess length. For the medial meniscus, the Pollard method is considered a satisfactory alternative. This study emphasized the importance of measuring the width and length of the meniscus independently during preoperative sizing for a meniscal allograft transplantation procedure. Using MRI as a gold standard, the study also proposed other less costly and satisfactory methods of obtaining such measurements.
There was a significant difference in the calculation of the wedge opening between the DM and NS. HTO without the aid of the NS could theoretically lead to undercorrection of the deformity.
Purpose and hypothesisIn preoperative sizing for meniscal transplantation, most authors take into consideration the length and width of the original meniscus, but not its height. This study aimed at evaluating (1) whether the meniscal height is associated with the meniscal length and width, (2) whether the heights of the meniscal segments are associated with the individual’s anthropometric data, (3) whether the heights of the meniscal segments are associated with each other in the same meniscus, and (4) the degree of symmetry of the meniscal dimensions between the right and left knees.MethodsIn this cross-sectional, observational study, two independent radiologists measured the meniscal length, width and height in knee magnetic resonance imaging scans obtained from 25 patients with patello-femoral pain syndrome. Reproducibility of measurements was calculated with intraclass correlation coefficients. Associations between the anthropometric data and the meniscal measurements, the meniscal length and width versus height, and the heights of the meniscal segments in the same meniscus were examined with Pearson’s correlation.ResultsInter-observer reliability was excellent (>0.8) for length and height and good (0.6–0.8) for width measurements. There was also excellent agreement (>0.8) for the length and width of the menisci in the right and left knees. The heights of the horns of the lateral meniscus showed good agreement (0.6–0.8), while the heights of the other meniscal segments had excellent agreement between the sides (>0.8). There were significant associations with generally low (r < 0.5) correlation between the heights of the meniscal segments and the lengths and widths of the menisci, between the meniscal height and anthropometric data, and between the heights of the meniscal segments in the same meniscus. Correlations between anthropometric data and meniscal length and width were generally high (r > 0.7).ConclusionsThere was excellent agreement between the meniscal dimensions of the right and left knees, and a weak association between the meniscal height with the meniscal width and length, between the height of the menisci with anthropometric data and between the heights of the segments in the same meniscus. The height of the meniscal segments may be a new variable in preoperative meniscal measurement.
BackgroundIn the field of anterior cruciate ligament (ACL) reconstruction, there is still no consensus regarding the proper fixation method and position of the tunnels. The primary objective of this paper was to describe a new fixation device, the Endo Tunnel Device (ETD®), for both techniques (transtibial and transportal), as well as the associated difficulties and the intraoperative and postoperative intercurrences. The secondary objective was to describe a preliminary clinical evaluation (6 months of follow-up) comparing these techniques.MethodsThis was a prospective, randomized study involving 80 patients with ACL reconstructions using the ETD® for femoral fixation. Forty patients underwent the transtibial technique, and 40 patients underwent the transportal technique. Patients were evaluated by radiography, physical examination, the KT1000 arthrometer, and Lysholm and the International Knee Documentation Committee (IKDC) scores.ResultsThere were more intraoperative intercurrences in the transportal group (soft tissue device fixation, short femoral tunnel, and short graft inside the tunnel). The IKDC scores were significantly better in the transportal group.ConclusionsThe ETD® was demonstrated to be a safe femoral fixation device in this trial; its use in both the transtibial and transportal techniques is technically simple and is associated with few intra- or postoperative complications.
Introduction: Although the results of anterior cruciate ligament (ACL) reconstruction are well documented in many studies, with good to excellent outcomes in most cases, some issues like tunnel positioning are still discussed and studied. Objective: To compare the objective and subjective clinical outcomes of ACL reconstruction using the transtibial and anteromedial portal techniques. Methods: Prospective randomized study of 80 patients undergoing anterior cruciate ligament reconstruction by the same surgeon, with 40 patients operated by the transtibial technique and 40 by anteromedial portal technique. The patients, 34 in the transtibial group and 37 in the anteromedial portal group (nine dropouts), were reassessed during a 2-year follow-up period. The clinical assessment consisted of physical examination, KT-1000TM evaluation, Lysholm score, and objective and subjective International Knee Documentation Committee -IKDC scores. Results: Regarding the Lachman and pivot shift tests, we observed more cases of instability in the transtibial group, but with no statistical significance (p=0.300 and p=0.634, respectively). Regarding the anterior drawer test, the groups presented similar results (p=0.977). Regarding KT-1000TM evaluation, the mean results were 1.44 for the transtibial group and 1.23 for the anteromedial portal group, with no statistical significance (p=0.548). We separated the objective IKDC scores into two groups: Group 1, IKDC A, and Group 2, IKDC B, C, or D, with no statistical significance (p=0.208). Concerning the Lysholm score, the transtibial group had a mean score of 91.32, and the anteromedial portal group had a mean score of 92.81. The mean subjective IKDC scores were 90.65 for the transtibial group and 92.65 for the anteromedial portal group. Three re-ruptures were encountered in the transtibial group and three in the anteromedial portal group. Conclusions: There were no significant differences in the subjective and objective clinical assessments among patients submitted to anterior cruciate ligament reconstruction using the transtibial or anteromedial portal techniques.
ObjectiveTo compare topical vs. intravenous tranexamic acid (TA) in total knee arthroplasty regarding blood loss and transfusion.MethodsNinety patients were randomized to receive TA intravenously (20 mg/kg in 100 mL of saline; group IV), topically (1.5 g in 50 mL of saline, sprayed over the operated site, before release of the tourniquet; topical group), or intravenous saline (100 mL with anesthesia; control group). The volume of drained blood in 48 h, the amount of transfused blood, and the serum levels of hemoglobin and hematocrit before and after surgery were evaluated.ResultsThe groups were similar for gender, age, weight, laterality, and preoperative hemoglobin and hematocrit levels (p > 0.2). The hemoglobin level dropped in all groups when comparing the preoperative and the 48-h evaluations: the control group decreased 3.8 mg/dL on average, while the IV group had a decrease of 3.0, and the topical group, of 3.2 (p = 0.019). The difference between the control and IV groups was confirmed by Bonferroni test (p = 0.020). The difference between the control group and the topical group was not significant (p = 0.130), although there was less reduction in hemoglobin in the topical group; the comparison between the IV group and the topical group was also not significant (p = 1.000).ConclusionUsing topic and IV tranexamic acid decreased blood loss and the need for transfusion in total knee arthroplasty. Topical application showed results similar to IV use regarding the need for blood transfusion, but without the possible side effects of IV administration.
scite is a Brooklyn-based startup that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.