The use of a computed tomography (CT) scanner specifically designed for breast imaging has been proposed by several investigators. In this study, the radiation dose due to breast CT was evaluated using Monte Carlo techniques over a range of parameters pertinent to the cone-beam pendant geometry thought to be most appropriate. Monte Carlo dose computations were validated by comparison with physical measurements made on a prototype breast CT scanner under development in our laboratory. The Monte Carlo results were then used to study the influence of cone angle, the use of a beam flattening ("bow-tie") filter, glandular fraction, breast length and source-to-isocenter distance. These parameters were studied over a range of breast diameters from 10 to 18 cm, and for both monoenergetic (8-140 keV by 1 keV intervals) and polyenergetic x-ray beams (30-100 kVp by 5 kVp intervals. Half value layer at 80 kVp = 5.3 mm Al). A parameter referring to the normalized glandular dose in CT (DgN(CT)) was defined which is the ratio of the glandular dose in the breast to the air kerma at isocenter. There was no significant difference (p = 0.743) between physically measured and Monte Carlo derived results. Fan angle, source-to-isocenter distance, and breast length have relatively small influences on the radiation dose in breast CT. Glandular fraction (0% versus 100%) for 10 cm breasts at 80 kVp had approximately a 10% effect on DgN(CT), and a 20% effect was observed for an 18 cm breast diameter. The use of a bow-tie filter had the potential to reduce breast dose by approximately 40%. X-ray beam energy and breast diameter had significant influence on the DgN(CT) parameters, with higher DgN(CT) values for higher energy beams and smaller breast diameters. DgN(CT) values (mGy/mGy) at 80 kVp ranged from 0.95 for an 8 cm diam 50% glandular breast to 0.78 for an 18 cm 50% glandular breast. The results of this investigation should be useful for those interested computing the glandular breast dose for geometries relevant to dedicated breast CT.
The magnitude of scatter contamination on a first-generation prototype breast computed tomography (CT) scanner was evaluated using the scatter-to-primary ratio (SPR) metric. The SPR was measured and characterized over a wide range of parameters relevant to breast CT imaging, including x-ray beam energy, breast diameter, breast composition, isocenter-to-detector distance, collimated slot thickness, and grid ratio. The results demonstrated that in the absence of scatter reduction techniques, the SPR levels for the average breast (e.g., 14 cm diameter 50/50 composition cylindrical phantom) are quite high (approximately 0.5 at the center of the phantom for 80 kVp in true cone-beam CT geometry), and increases as the diameter of the phantom is increased (to approximately 1.0 at the center of a 18 cm diameter 50/50 phantom). The x-ray beam energy and the phantom compositions had only minimal impact on the measured SPR. When an ideal bowtie filter was used, the SPRs at the central axis of the 14 and 18 cm cylindrical phantoms were reduced while the SPRs at the edge of the phantoms were increased. Lastly, collimation in the vertical direction had a significant impact on the SPRs at the central axis of the phantoms. These high SPR levels might lead to cupping artifacts and increased noise in the reconstructed CT images, and this suggests that efficient scatter rejection and/or correction techniques may be required to improve the quality and accuracy of cone beam CT images.
The use of breast computed tomography (CT) as an alternative to mammography in some patients is being studied at several institutions. However, the radiation dosimetry issues associated with breast CT are markedly different than in the case of mammography. In this study, the spectral properties of an operational breast CT scanner were characterized both by physical measurement and computer modeling of the kVp-dependent spectra, from 40 to 110 kVp (Be window W anode with 0.30 mm added Cu filtration). Previously reported conversion factors, normalized glandular dose for CT-DgN(ct), derived from Monte Carlo methods, were used in concert with the output spectra of the breast scanner to compute the mean glandular dose to the breast based upon different combinations of x-ray technique factors (kVp and mAs). The mean glandular dose (MGD) was measured as a function of the compressed breast thickness (2-8 cm) and three different breast compositions (0%, 50%, and 100% glandular fractions) in four clinical mammography systems in our institution. The average MGD from these four systems was used to compute the technique factors for breast CT systems that would match the two-view mammographic dose levels. For a 14 cm diameter breast (equivalent to a 5 cm thick compressed breast in mammography), air kerma levels at the breast CT scanner's isocenter (468 mm from the source) of 4.4, 6.4, and 9.0 mGy were found to deliver equivalent mammography doses for 0%, 50%, and 100% glandular breasts (respectively) at 80 kVp. At 80 kVp (where air kerma was 11.3 mGy/100 mAs at the isocenter), 57 mAs (integrated over the entire scan) was required to match the mammography dose for a 14 cm 50% glandular breast. At 50 kVp, 360 mAs is required to match mammographic dose levels. Tables are provided for both air kerma at the isocenter and mAs for 0%, 50%, and 100% glandular breasts. Other issues that impact breast CT technique factors are also discussed.
A pendant-geometry, cone-beam breast CT scanner has been constructed and is undergoing thorough testing in our facility. The system is capable of acquiring 30 frames/sec in 2×2 binning mode (1024×768 pixels) using a flat panel detector coupled to a thallium-doped cesium iodide scintillator. The DQE of the detector system for RQA5 and RQA9x-ray beam qualities were computed, and the low frequency DQE values were 65% and 57% respectively at approximately 16 µR/frame. The results also shown that minor improvements in DQE are achieved for exposures greater than 16 µR/frame. It is expected that the scanner will be available for the imaging of human volunteers in the first half of 2004.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.