Ventricular septal rupture (VSR) after acute myocardial infarction is increasingly rare in the percutaneous coronary intervention era but mortality remains high. Prompt diagnosis is key and definitive surgery, though challenging and associated with high mortality, remains the treatment of choice. Alternatively, delaying surgery in stable patients may provide better results. Prolonged medical management is usually futile, but includes afterload reduction and intra-aortic balloon pump placement. Using full mechanical support to delay surgery is an attractive option, but data on success is limited to case reports. Finally, percutaneous VSR closure may be used as a temporizing measure to reduce shunt, or for patients in the sub-acute to chronic period whose comorbidities preclude surgical repair.
Repair durability is greatest in patients with isolated posterior leaflet prolapse who have posterior leaflet resection and annuloplasty. Chordal shortening, annuloplasty alone, and leaflet resection without annuloplasty jeopardize late results.
Background
Increased life expectancy and younger patients’ desire to avoid lifelong anticoagulation requires a better understanding of bioprosthetic valve failure. This study evaluates risk factors associated with explantation for structural valve deterioration (SVD) in a long-term series of Carpentier-Edwards PERIMOUNT aortic valves (AV).
Methods
From June 1982 to January 2011, 12,569 patients underwent AV replacement with Edwards Lifesciences Carpentier-Edwards PERIMOUNT stented bovine pericardial prostheses, models 2700PM (n = 310) or 2700 (n = 12,259). Mean age was 71 ± 11 years (range, 18 to 98 years). 93% had native AV disease, 48% underwent concomitant coronary artery bypass grafting, and 26% had additional valve surgery. There were 81,706 patient-years of systematic follow-up data available for analysis. Demographics, intraoperative variables, and 27,386 echocardiographic records were used to identify risks for explant for SVD and assess longitudinal changes in transprosthesis gradients using time-varying covariable analyses.
Results
Three hundred fifty-four explants were performed, with 41% related to endocarditis and 44% to SVD. Actuarial estimates of explant for SVD at 10 and 20 years were 1.9% and 15% overall, respectively, and in patients younger than 60 years, 5.6% and 46%, respectively. Younger age (p < 0.0001), lipid-lowering drugs (p = 0.002), prosthesis–patient mismatch (p = 0.001), and higher postoperative peak and mean AV gradients were associated with explant for SVD (p < 0.0001). The effect of gradient on SVD was greatest in patients younger than 60 years.
Conclusions
Durability of the Carpentier-Edwards PERIMOUNT aortic valve is excellent even in younger patients. Explant for SVD is related to gradient at implantation, especially in younger patients. Strategies to reduce early postoperative AV gradients, such as root enlargement or more efficient prostheses, should be considered.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.