Recent technological innovations have enabled the development of a new class of dynamic (vibration-insensitive) interferometer based on a CCD pixel-level phase-shifting approach. We present theoretical and experimental results for an interferometer based on this pixelated phase-shifting technique. Analyses of component errors and instrument functionality are presented. We show that the majority of error sources cause relatively small magnitude peak-to-valley errors in measurement of the order of 0.002-0.005lambda. These errors are largely mitigated by high-rate data acquisition and consequent data averaging.
A division-of-focal-plane polarimeter based on a dichroic dye and liquid crystal polymer guest-host system is presented. Two Stokes polarimeters are demonstrated: a linear Stokes and the first ever Full-Stokes division-of-focal-plane polarimeter. The fabrication, packaging, and characterization of the systems are presented. Finally, optimized polarimeter designs are discussed for future works.
The largest limitation of phase-shifting interferometry for optical testing is the sensitivity to the environment, both vibration and air turbulence. In many situations the measurement accuracy is limited by the environment and sometimes the environment is sufficiently bad that the measurement cannot be performed. Recently there have been several advances in dynamic interferometry techniques for reducing effects of vibration. This talk will describe and compare two dynamic interferometry techniques; simultaneous phase-shifting interferometry and a special form of spatial carrier interferometry utilizing a micropolarizer phase-shifting array.
In this paper, a full-Stokes imaging polarimeter operating at 580 nm using an array of elliptical polarizers is presented. The division-of-focal-plane polarimeter utilizes a set of four optimized measurements which represent a regular tetrahedron inscribed in the Poincaré sphere. Results from the device fabrication, instrument calibration and characterization are presented. The performance of the optimized full Stokes polarimeter, as defined by size of the standard deviation of the degree of circular polarization, is found to be approximately five times better than the performance of the simple full-Stokes polarimeter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.