Background: In recent years, glass fibres have been used to strengthen denture base resins. A major difficulty in using reinforcing fibres with multiphase acrylic resins, such as powder liquid resins, is inadequate impregnation of the fibres with the resin.
Methods: This investigation examined the reinforcing effect of glass fibres on the fracture resistance and flexural strength of acrylic denture base resins. Eighty identical specimens were formed in specially designed moulds in accordance with the manufacturer's recommendations. The four experimental groups were prepared and these consisted of conventional acrylic resin and the same resin reinforced with glass fibres. Ten specimens were fabricated in a standardized fashion for each experimental group. Flexural strength was tested using a 3‐point universal testing machine.
Results: In this study, statistically significant differences were found in the flexural strength of the specimens (P<0.05). The injection‐moulded, fibre‐reinforced group had significantly lower flexural strength than the injection‐moulded group (P<0.001), and the microwave‐moulded, fibre‐reinforced group had lower flexural strength than the microwave‐moulded group. The fracture resistance was significantly higher in the injection‐moulded, fibre‐reinforced group than in the injection‐moulded group (P<0.05), and the fracture resistance was significantly higher in the microwave‐moulded, fibre‐reinforced group than in the microwave‐moulded group.
Conclusion: Within the limitations of this study, the flexural strength of heat‐polymerized PMMA denture resin was improved after reinforcement with glass fibres. It may be possible to apply these results to distal extension partial and complete denture bases.
Objectives:To compare the finger pressure applied by dentists during cementation and to examine the effect of gender and time of day on finger pressure.Methods:Fifteen dentists (9 males, 6 females) formed a study group and 10 master dies in premolar shape and Turcom Cera all-ceramic crowns were prepared to measure the maximum finger pressure applied by dentists during cementation. The dentists performed a total of 300 cementation processes. One-way analysis of variance and independent t tests were used to evaluate the results.Results:A statistically significant difference was found in the amount of pressure applied during cementation (P<.005). However, there was no significant difference for time of day or gender according to one-way analysis of variance.Conclusions:Our results show that finger pressure varies by dentist. For this reason, the optimum pressure should be determined exactly. Special equipment or an apparatus could be developed to apply that pressure.
Blood contamination of abutment screw holes was shown to significantly decrease RTVs. Blood contamination may result in greater loosening of implant screws in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.