Summary Background Although therapeutic hypothermia reduces death or disability after neonatal encephalopathy in high-income countries, its safety and efficacy in low-income and middle-income countries is unclear. We aimed to examine whether therapeutic hypothermia alongside optimal supportive intensive care reduces death or moderate or severe disability after neonatal encephalopathy in south Asia. Methods We did a multicountry open-label, randomised controlled trial in seven tertiary neonatal intensive care units in India, Sri Lanka, and Bangladesh. We enrolled infants born at or after 36 weeks of gestation with moderate or severe neonatal encephalopathy and a need for continued resuscitation at 5 min of age or an Apgar score of less than 6 at 5 min of age (for babies born in a hospital), or both, or an absence of crying by 5 min of age (for babies born at home). Using a web-based randomisation system, we allocated infants into a group receiving whole body hypothermia (33·5°C) for 72 h using a servo-controlled cooling device, or to usual care (control group), within 6 h of birth. All recruiting sites had facilities for invasive ventilation, cardiovascular support, and access to 3 Tesla MRI scanners and spectroscopy. Masking of the intervention was not possible, but those involved in the magnetic resonance biomarker analysis and neurodevelopmental outcome assessments were masked to the allocation. The primary outcome was a combined endpoint of death or moderate or severe disability at 18–22 months, assessed by the Bayley Scales of Infant and Toddler Development (third edition) and a detailed neurological examination. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov , NCT02387385 . Findings We screened 2296 infants between Aug 15, 2015, and Feb 15, 2019, of whom 576 infants were eligible for inclusion. After exclusions, we recruited 408 eligible infants and we assigned 202 to the hypothermia group and 206 to the control group. Primary outcome data were available for 195 (97%) of the 202 infants in the hypothermia group and 199 (97%) of the 206 control group infants. 98 (50%) infants in the hypothermia group and 94 (47%) infants in the control group died or had a moderate or severe disability (risk ratio 1·06; 95% CI 0·87–1·30; p=0·55). 84 infants (42%) in the hypothermia group and 63 (31%; p=0·022) infants in the control group died, of whom 72 (36%) and 49 (24%; p=0·0087) died during neonatal hospitalisation. Five serious adverse events were reported: three in the hypothermia group (one hospital readmission relating to pneumonia, one septic arthritis, and one suspected venous thrombosis), and two in the control group (one related to desaturations during MRI and other because of endotracheal tube displacement during transport for MRI). No adverse events were considered causally related to the study intervention. Interpretatio...
Recently voltage-source or current-source inverter based various FACTS devices have been used for flexible power flow control, secure loading, damping of power system oscillation and even for the stabilization of wind energy generation. In this paper, we propose the static synchronous compensator (STATCOM) based on voltage source converter (VSC) PWM technique to stabilize grid connected wind generator system. A simple control strategy of STATCOM is adopted where only measurement of rms voltage at the wind generator terminal is needed. Fuzzy logic controller rather than conventional PI controller is proposed as the control methodology of STATCOM. Multi-mass shaft model of wind turbine generator system (WTGS) is also considered as shaft modeling has a big influence on the transient performance of WTGS. Transient performance of STATCOM connected WTGS is compared also with that of pitch controlled WTGS. Both symmetrical and unsymmetrical faults are analyzed. Moreover, the steady state performance of STATCOM connected WTGS is analyzed. It is reported that STATCOM can reduce the voltage fluctuation significantly. Finally STATCOM is applied to a wind park model with multiple wind generators. Comprehensive results are presented to assess the performance of STATCOM connected WTGS, where the simulations have been done by PSCAD/EMTDC.
Neural tube defect (NTD) is a multi-factorial disorder in which nutritional, genetic and environmental factors are involved. Among the nutritional factors, low level of serum zinc has been reported from different parts of the world. This hospital-based case-control study was conducted with the objective of finding the relationship between serum zinc level in newborns and their mothers and NTDs in a Bangladeshi population. The study was conducted during August 2006–July 2007 at the Bangabandhu Sheikh Mujib Medical University (BSMMU) in Dhaka. In total, 32 mothers and their newborns with NTDs were included as cases and another 32 mothers with their normal babies were included as controls. Concentration of serum zinc was determined by pyro-coated graphite furnace atomic absorption spectrophotometer (GF-AAS). The mean age of the case and control mothers was 25.28 years and 24.34 years respectively. The mean gestational age of the case newborns was 36.59 weeks and that of the control newborns was 37.75 weeks. The mean serum zinc level of the case and control mothers was 610.2 μg/L and 883.0 μg/L respectively (p<0.01). The mean serum zinc level of the case and control newborns was 723 μg/L and 1,046 μg/L respectively (p<0.01). In both case and control groups, the serum zinc level of the newborns positively correlated with that of the mothers. The serum zinc levels of the mothers and newborns negatively correlated with NTDs. Mothers with serum zinc level lower than normal were 7.66 [95% confidence interval (CI) 2.5-23.28] times more likely to have NTDs compared to the normal zinc level of mothers. After adjusting for the zinc level of the newborns, parity, and age of the mothers, this risk reduced 1.61 times [confidence interval (CI) 95% 0.24-8.77]. On the other hand, the low serum zinc level of the newborns was 7.22 times more associated with NTDs compared to the newborns with the normal serum zinc level, which was statistically significant (p=0.001). After adjusting for other factors, such as maternal age and parity, newborns with the low serum zinc level was found to be 9.186 times more likely to be associated with NTDs compared to newborns with normal serum zinc level. Based on the findings, it may be concluded that the low serum zinc levels of newborns may be associated with NTDs. To confirm these findings, a further study with a larger sample-size is recommended. Moreover, a follow-up study with zinc supplementation to pregnant women and its impact on NTDs is also recommended.
This paper describes the design and implementation of an energy efficient solar tracking system from a normal mechanical single axis to a hybrid dual axis. For optimizing the solar tracking mechanism electromechanical systems were evolved through implementation of different evolutional algorithms and methodologies. To present the tracker, a hybrid dual-axis solar tracking system is designed, built, and tested based on both the solar map and light sensor based continuous tracking mechanism. These light sensors also compare the darkness and cloudy and sunny conditions assisting daily tracking. The designed tracker can track sun’s apparent position at different months and seasons; thereby the electrical controlling device requires a real time clock device for guiding the tracking system in seeking solar position for the seasonal motion. So the combination of both of these tracking mechanisms made the designed tracker a hybrid one. The power gain and system power consumption are compared with a static and continuous dual axis solar tracking system. It is found that power gain of hybrid dual axis solar tracking system is almost equal to continuous dual axis solar tracking system, whereas the power saved in system operation by the hybrid tracker is 44.44% compared to the continuous tracking system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.