We have used the wavelet transform to evaluate the time-frequency content of laser-Doppler flowmetry (LDF) signals measured simultaneously on the surfaces of free microvascular flaps deprived of sympathetic nerve activity (SNA), and on adjacent intact skin, in humans. It was thereby possible to determine the frequency interval within which SNA manifests itself in peripheral blood flow oscillations. The frequency interval from 0.0095 to 2 Hz was examined and was divided into five subintervals: I, approximately 0.01 Hz; II, approximately 0.04 Hz; III, approximately 0.1 Hz; IV, approximately 0.3 Hz; and V, approximately 1 Hz. The average value of the LDF signal in the time domain as well as the mean amplitude and total power in the interval from 0.0095 to 2 Hz and amplitude and power within each of the five subintervals were significantly lower for signals measured on the free flap (P < 0.002). The normalized spectral amplitude and power in the free flap were significantly lower in only two intervals: I, from 0.0095 to 0.021 Hz; and II, from 0.021 to 0.052 Hz (P < 0.05); thus indicating that SNA is manifested in at least one of these frequency intervals. Because interval I has recently been shown to be the result of vascular endothelial activity, we conclude that we have identified SNA as influencing blood flow oscillations in normal tissues with repetition times of 20-50 s or frequencies of 0.02-0.05 Hz.
Iontophoresis currents are used in the transcutaneous delivery of vasoactive substances for noninvasive assessment of skin vascular properties. The blood flow rate can be recorded by laser Doppler flowmetry (LDF), its average value and the amplitudes of its oscillatory components being used to evaluate the effect of the drugs. Because non-drug-specific, current-induced, vasodilation could confound the interpretation of the response, we have investigated the effect of currents of both polarities on the spectral components of the LDF signal in the absence of vasoactive substances. It was recorded for healthy volunteers with both high conductance (5 mol/l NaCl) and low conductance (deionized water) electrolytes. The oscillatory components were analysed by wavelet transform within 0.0095-1.6 Hz, divided into five sub-intervals. Only cathodal iontophoresis with deionized water increased the oscillatory energy and amplitude. It did so at all frequencies, but none of the sub-intervals associated with vasodilation (0.0095-0.145 Hz) was selectively affected compared to the others.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.