This Feature Article aims to provide an in‐depth overview of the recently developed molding technologies termed capillary force lithography (CFL) that can be used to control the cellular microenvironment towards cell and tissue engineering. Patterned polymer films provide a fertile ground for controlling various aspects of the cellular microenvironment such as cell–substrate and cell–cell interactions at the micro‐ and nanoscale. Patterning thin polymer films by molding typically involves several physical forces such as capillary, hydrostatic, and dispersion forces. If these forces are precisely controlled, the polymer films can be molded into the features of a polymeric mold with high pattern fidelity and physical integrity. The patterns can be made either with the substrate surface clearly exposed or unexposed depending on the pattern size and material properties used in the patterning. The former (exposed substrate) can be used to adhere proteins or cells on pre‐defined locations of a substrate or within a microfluidic channel using an adhesion‐repelling polymer such as poly(ethylene glycol) (PEG)‐based polymer and hyaluronic acid (HA). Also, the patterns can be used to co‐culture different cells types with molding‐assisted layer‐by‐layer deposition. In comparison, the latter (unexposed substrate) can be used to control the biophysical surrounding of a cell with tailored mechanical properties of the material. The surface micropatterns can be used to engineer cellular and multi‐cellular architecture, resulting in changes of the cell shape and the cytoskeletal structures. Also, the nanoscale patterns can be used to affect various aspects of the cellular behavior, such as adhesion, proliferation, migration, and differentiation.
A label-free microfluidic method for separation and enrichment of human breast cancer cells is presented using cell adhesion as a physical marker. To maximize the adhesion difference between normal epithelial and cancer cells, flat or nanostructured polymer surfaces (400 nm pillars, 400 nm perpendicular, or 400 nm parallel lines) were constructed on the bottom of polydimethylsiloxane (PDMS) microfluidic channels in a parallel fashion using a UV-assisted capillary moulding technique. The adhesion of human breast epithelial cells (MCF10A) and cancer cells (MCF7) on each channel was independently measured based on detachment assays where the adherent cells were counted with increasing flow rate after a pre-culture for a period of time (e.g., one, two, and four hours). It was found that MCF10A cells showed higher adhesion than MCF7 cells regardless of culture time and surface nanotopography at all flow rates, resulting in label-free separation and enrichment of cancer cells. For the cell types used in our study, an optimum separation was found for 2 hours pre-culture on the 400 nm perpendicular line pattern followed by flow-induced detachment at a flow rate of 200 ml min 21 . The fraction of MCF7 cells was increased from 0.36 ¡ 0.04 to 0.83 ¡ 0.04 under these optimized conditions.
We present a simple cell docking method induced by receding meniscus to capture non-adherent yeast cells onto microwells inside a microfluidic channel. Microwells were fabricated either by capillary moulding of UV curable polyurethane acrylate (PUA) onto glass substrate or direct replica moulding of poly(dimethyl siloxane) (PDMS). A cell suspension of the budding yeast, Saccharomyces cerevisiae, was introduced into the microfluidic channel by surface tension driven capillary flow and a receding meniscus was subsequently generated by evaporation. As the meniscus progressed, one to multiple yeast cells were spontaneously captured onto microwells by lateral capillary force created at the bottom of the meniscus. Using this cell-based platform, we observed the response of yeast cells upon stimulation by a mating pheromone (a-factor) by monitoring the expression of green fluorescent protein (GFP) with time. It was observed that a-factor triggered the expression of GFP at 60 min after stimulation and the fluorescence intensity was sustained for an additional 60 min without changes.
Extracting single-cell information during cellular responses to external signals in a high-throughput manner is an essential step for quantitative single-cell analyses. Here, we have developed a simple yet robust microfluidic platform for measuring time-course single-cell response on a large scale. Our method combines a simple microwell-based cell docking process inside a patterned microfluidic channel, with programmable time-course live-cell imaging and software-aided fluorescent image processing. The budding yeast, Saccharomyces cerevisiae (S. cerevisiae), cells were individually captured in microwells by multiple sweeping processes, in which a cell-containing solution plug was actively migrating back and forth several times by a finger-pressure induced receding meniscus. To optimize cell docking efficiency while minimizing unnecessary flooding in subsequent steps, circular microwells of various channel dimensions (4-24 µm diameter, 8 µm depth) along with different densities of cell solution (1.5-6.0 × 10(9) cells per mL) were tested. It was found that the microwells of 8 µm diameter and 8 µm depth allowed for an optimal docking efficiency (>90%) without notable flooding issues. For quantitative single-cell analysis, time-course (time interval 15 minute, for 2 hours) fluorescent images of the cells stimulated by mating pheromone were captured using computerized fluorescence microscope and the captured images were processed using a commercially available image processing software. Here, real-time cellular responses of the mating MAPK pathway were monitored at various concentrations (1 nM-100 µM) of mating pheromone at single-cell resolution, revealing that individual cells in the population showed non-uniform signaling response kinetics.
We present a simple analytical method to measure adhesion of human umbilical vein endothelial cells (HUVECs) and calf pulmonary artery endothelial cells (CPAEs) using nanopatterned, biodegradable poly(lactic-co-glycolic acid) (PLGA) surfaces for potential applications to artificial tissue-engineered blood vessel. Various nanostructured PLGA surfaces (350 nm wide ridges/350 nm grooves, 350 nm ridges/700 nm grooves, 350 nm ridges/1750 nm grooves, 700 nm ridges/350 nm grooves, 1050 nm ridges/350 nm grooves, 1750 nm ridges/350 nm grooves) and flat (unpatterned) surfaces were fabricated on the bottom of polydimethylsiloxane (PDMS) microfluidic channel of 2 mm width and 60 microm height by using thermal imprinting and irreversible channel bonding. To measure adhesion strength of HUVECs and CPAEs, the cells were exposed to a range of shear stress (12, 40, and 80 dyn/cm(2)) within the channels for 20 min after a preculture for 3 days and the remaining cells were counted under each condition. The highest adhesion strength was found on the surface of 700 nm wide ridges, 350 nm wide grooves for both cell types. The enhanced adhesion on nanopatterned surfaces can be attributed to two aspects: (i) contact guidance along the line direction and (ii) clustered focal adhesions. In particular, the contact guidance induced cell alignment along the line directions, which in turn lowers wall shear stress applied to the cell surface, as supported by a simple hydrodynamic model based on cell morphology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.