Reinforced concrete (RC) structures represent one of the most widespread building systems around the world. This paper deals with the optimization of load-bearing RC structures in terms of cost and environmental impact. The results of the optimization are the dimensions and reinforcement of structural elements for which the total construction costs and environmental impacts are the lowest. Six variants of RC building structures were designed and analyzed in a case study. The construction cost was evaluated on the basis of the national pricing system. The life cycle assessment (LCA) characterization model according to the ReCiPe methodology version 1.08 was used to assess environmental impacts. The main motivation of this article was to show the possibilities of the multi-criteria optimization of a load-bearing structure, not only from a structural point of view but also from economic and environmental points of view. The presented conclusions correspond to this specific construction of the RC structure used in the case study and may not be generalized. Nevertheless, they point to certain trends and patterns that can also be used in the design of other reinforced concrete structures. The method used in this case study could be applied to the analysis of other structures using specific datasets for cost and environmental impact evaluation.
Use of high performance concrete with reinforcement made of technical textile is increasing and new applications are being found. This paper presents new technology for the lightening of the panels made of textile reinforced concrete, which is being developed. The main focus of this research is to produce concrete elements suitable for use as facade panels with the least possible weight and environmental impact. Mechanical characteristics were measured on testing specimens with thickness of 18 mm with lightening representing 47% of their volume. Minimum thickness of concrete was 4 mm and therefore the reinforcement was covered by approximately 1.5 mm of concrete matrix. The strength of experimental test panels was measured in four-point bending stress test. Due to one-sided lightening and asymmetrical cross-section therefore, the tests were performed in both directions. For better interpretation of the results were the specimens of lightened panels tested alongside non-lightened specimens with the same thickness. Based on measured values, maximal dimensions of lightened facade panels were designed.
This article deals with optimal dosage of metakaolin as addition in high performance concrete. The main criteria for assessing the optimal dosage of metakaolin was compressive strength, rheological behaviour and economic benefits. Metakaolin was added to the mixture of high performance concrete in the range from 0 to 25% weight of cement. The comparison of metakaolin and microsilica, which is often used by concrete producers due to its excellent properties, is also performed in this article. The experiments showed that using metakaolin as addition in high performance concrete affects the compressive strength and rheological behaviour positively. While the compressive strength increases especially at lower doses of metakaolin and at higher doses remained unchanged, changes in rheological behaviour were most obvious at the higher doses. From this point of view, it is possible to recommend a higher dose of metakaolin.
High performance concrete reinforced by technical textiles has found a wide range of applications in recent years. One of the most widespread is the use of this composite for the very thin facade panels of various shapes and technical solutions. This paper presents an unique way how to lighten the facade panels made of high performance concrete (HPC) reinforced by technical textiles, which are additionally equipped with LEDs, so that a sufficient distance can be watch programmed based image displays.
Development of extremely thin concrete structures and demand for extremely thin elements are the reason of using composite non-traditional materials as reinforcement. Steel reinforcement is not very chemically resistant and it limits the thickness because of the required concrete cover as protection. This is the reason why textile reinforced concrete (TRC) going to be very famous and modern material. TRC in combination with fine grain high performance concrete (HPC) allows a significant saving of concrete. Due to its non-corrosive properties of composite technical textiles it is possible to design very subtle structures and elements. TRC and HPC in general are developed at the Faculty of Civil Engineering and the Klokner Institute, CTU in Prague. This present paper investigates the cohesion influence of textile reinforcement on four point bending test. All small experimental panels were reinforced with the same 3D technical textile from AR-glass roving with different type of cover layer. Different conditions of interaction between technical textiles and HPC were ensured by modified surface using silica sand and silica flour.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.