HighlightsWe report here a case of a 62 years old patient with charcot arthropathy at her left knee developed one year after spinal stenosis surgery.The patient’s knee joint was already beyond the fragmentation and coalescence stages at the moment of physical examination.Unsuccessful spinal surgery affected polyneuropathy and migrated the level of the sensorineural loss proximally.Elevated level of sensorineural loss resulted in Charcot knee joint in a short period of time.
The role of the platelet-to-lymphocyte ratio and neutrophil-to-lymphocyte ratio in the prediction of length and cost of hospital stay in patients with infected diabetic foot ulcers: A retrospective comparative study
Background
It has been suggested that the posterior tibial slope (PTS) plays an important role in increasing the anteroposterior stability following total knee arthroplasty. Although the relationship between the PTS and the flexion range has been investigated many times, studies on the relationship between PTS and anterior-posterior stability are limited. The primary aim of this study was to investigate the relationship and effects of PTS on anteroposterior stability in posterior cruciate retainer total knee arthroplasty.
Methods
154 primary TKAs were identified retrospectively to analyze the any association between PTS and anteroposterior laxity following posterior cruciate-retaining total knee arthroplasty in the overall study populations. Anteroposterior displacement was measured at the final follow-up based on the following two procedures: KT-1000 arthrometer and sagittal drawer radiographic images. In addition, the relationship between PTS and functional scores-ROM was examined.
Results
There was no correlation between patients’ posterior tibial slope and postoperative VAS (r: -0.060, p:0.544), WOMAC (r:0.037, p:0.709), KSS (r: -0.073, p:0.455). In addition, there was no significant correlation between postoperative knee ROM and postoperative PTS (r:0.159, p:0.106). Moreover, no correlation was found between KT-1000 arthrometer and 20 degrees AP translation with PTS. There was a negative correlation between PTS and 70 degrees AP translation (r: -0.281, p:0.008).
Conclusions
This study aimed to clarify the association between instability and AP laxity in flexion of implanted knees, and to determine what degree of AP laxity results of instability. A fundamental finding of this study was that; the optimum TS angle to increase anterior-posterior stability after total knee arthroplasty is between ≥ 4 to < 6 degrees, we also proved that there is no relationship between stability and patient satisfaction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.