There remains a great challenge in the sensitive detection of microRNA because of the short length and low abundance of microRNAs in cells. Here, we have demonstrated an ultrasensitive detection platform for microRNA by combining the tetrahedral DNA nanostructure probes and hybridization chain reaction (HCR) amplification. The detection limits for DNA and microRNA are 100 aM and 10 aM (corresponding to 600 microRNAs in a 100 μL sample), respectively. Compared to the widely used supersandwich amplification, the detection limits are improved by 3 orders of magnitude. The uncontrolled surface immobilization and consumption of target molecules that limit the amplification efficiency of supersandwich are eliminated in our platform. Taking advantage of DNA nanotechnology, we employed three-dimensional tetrahedral DNA nanostructure as the scaffold to immobilize DNA recognition probes to increase the reactivity and accessibility, while DNA nanowire tentacles are used for efficient signal amplification by capturing multiple catalytic enzymes in a highly ordered way. The synergetic effect of DNA tetrahedron and nanowire tentacles have proven to greatly improve sensitivity for both DNA and microRNA detection.
Self-assembled DNA nanostructures with precise sizes allow a programmable "soft lithography" approach to engineer the interface of electrochemical DNA sensors. By using millimeter-sized gold electrodes modified with several types of tetrahedral DNA nanostructures (TDNs) of different sizes, both the kinetics and thermodynamics of DNA hybridization were profoundly affected. Because each DNA probe is anchored on an individual TDN, its lateral spacing and interactions are finely tuned by the TDN size. By simply varying the size of the TDNs, the hybridization time was decreased and the hybridization efficiency was increased. More significantly, the detection limit for DNA detection was tuned over four orders of magnitude with differentially nanostructured electrodes, and achieved attomolar sensitivity with polymeric enzyme amplification.
The occurrence and prognosis of many complex diseases, such as cancers, is associated with the variation of various molecules, including DNA at the genetic level, RNA at the regulatory level, proteins at the functional level and small molecules at the metabolic level (defined collectively as multilevel molecules). Thus it is highly desirable to develop a single platform for detecting multilevel biomarkers for early-stage diagnosis. Here we report a protocol on DNA-nanostructure-based programmable engineering of the biomolecular recognition interface, which provides a universal electrochemical biosensing platform for the ultrasensitive detection of nucleic acids (DNA/RNA), proteins, small molecules and whole cells. The protocol starts with the synthesis of a series of differentially sized, self-assembled tetrahedral DNA nanostructures (TDNs) with site-specifically modified thiol groups that can be readily anchored on the surface of a gold electrode with high reproducibility. By exploiting the rigid structure, nanoscale addressability and versatile functionality of TDNs, one can tailor the type of biomolecular probes appended on individual TDNs for the detection of specific molecules of interest. Target binding occurring on the gold surface patterned with TDNs is quantitatively translated into electrochemical signals via a coupled enzyme-based catalytic process. This uses a sandwich assay strategy in which biotinylated reporter probes recognize TDN-bound target biomolecules, which then allow binding of horseradish-peroxidase-conjugated avidin (avidin-HRP). Hydrogen peroxide (H2O2) is then reduced by avidin-HRP in the presence of TMB (3,3',5,5'-tetramethylbenzidine) to generate a quantitative electrochemical signal. The time range for the entire protocol is ∼1 d, whereas the detection process takes ∼30 min to 3 h.
MicroRNAs (miRNAs) have been identified as promising cancer biomarkers due to their stable presence in serum. As an alternative to PCR-based homogenous assays, surface-based electrochemical biosensors offer great opportunities for low-cost, point-of-care tests (POCTs) of disease-associated miRNAs. Nevertheless, the sensitivity of miRNA sensors is often limited by mass transport and crowding effects at the water-electrode interface. To address such challenges, we herein report a DNA nanostructure-based interfacial engineering approach to enhance binding recognition at the gold electrode surface and drastically improve the detection sensitivity. By employing this novel strategy, we can directly detect as few as attomolar (<1, 000 copies) miRNAs with high single-base discrimination ability. Given that this ultrasensitive electrochemical miRNA sensor (EMRS) is highly reproducible and essentially free of prior target labeling and PCR amplification, we also demonstrate its application by analyzing miRNA expression levels in clinical samples from esophageal squamous cell carcinoma (ESCC) patients.
Receptor−ligand interactions (RLIs) that play pivotal roles in living organisms are often depicted with the classic keys-and-locks model. Nevertheless, RLIs on the cell surface are generally highly complex and nonlinear, partially due to the noncontinuous and dynamic distribution of receptors on extracellular membranes. Here, we develop a tetrahedral DNA framework (TDF)-programmed approach to topologically engineer RLIs on the cell membrane, which enables active recruitment-binding of clustered receptors for high-affinity capture of circulating tumor cells (CTCs). The four vertices of a TDF afford orthogonal anchoring of ligands with spatial organization, based on which we synthesized n-simplexes harboring 1−3 aptamers targeting epithelial cell adhesion molecule (EpCAM) that are overexpressed on the membrane of tumor cells. The 2-simplex with three aptamers not only shows increased binding affinity (∼19-fold) but prevents endocytosis by cells. By using 2-simplex as the capture probe, we demonstrate the high-efficiency CTC capture, which is challenged in real clinical breast cancer patient samples. This TDFprogrammed platform thus provides a powerful means for studying RLIs in physiological settings and for cancer diagnosis.
Sensitive detection of cancer cells plays a critically important role in the early detection of cancer and cancer metastasis. However, because circulating tumor cells are extremely rare in peripheral blood, the detection of cancer cells with high analytical sensitivity and specificity remains challenging. Here, we have demonstrated a simple, sensitive and specific detection of cancer cells with the detection sensitivity of four cancer cells, which is lower than the cutoff value with respect to correlation with survival outcomes as well as predictive of metastatic disease in clinical diagnostics. We re-engineered the hybridization chain reaction (HCR) to multibranched HCR (mHCR) that can produce long products with multiple biotins for signal amplification and multiple branched arms for multivalent binding. The capturing gold surface is modified with DNA tetrahedral probes, which provide superior hybridization conditions for the multivalent binding. The synergetic effect of mHCR amplification and multivalent binding lead to the high sensitivity of our detection platform.
Turn up the volume: In a simple and highly sensitive aptamer‐based assay that relies on the ability of nanomaterials to protect DNA from nuclease cleavage, the aptamer is released from the nanomaterial when challenged with a target. The nuclease then cleaves the free aptamer and releases the target, which can initiate a new cycle. Recycling of the target in this way leads to significant signal amplification (see diagram).
Because of the short size and low abundance of microRNAs, it is challenging to develop fast, inexpensive, and simple biosensors to detect them. In this work, we have demonstrated a new generation (the third generation) of E-DNA sensor for the sensitive and specific detection of microRNAs. Our third generation of E-DNA sensor can sensitively detect microRNA target (microRNA-141) as low as 1 fM. The excellent specificity has been demonstrated by its differential ability to the highly similar microRNA analogues. In our design, the use of DNA tetrahedron ensures the stem-loop structure in well controlled density with improved reactivity. The regulation of the thermodynamic stability of the stem-loop structure decreases the background signal and increases the specificity as well. The enzymes attached bring the electrocatalytic signal to amplify the detection. The combination of these effects improves the sensitivity of the E-DNA sensor and makes it suitable to the microRNA detection. Finally, our third generation of E-DNA sensor is generalizable to the detection of other micro RNA targets (for example, microRNA-21).
scite is a Brooklyn-based startup that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2023 scite Inc. All rights reserved.
Made with 💙 for researchers