Quantification of CINE phase contrast (PC)-MRI data is a challenging task because of the limited spatiotemporal resolution and signal-to-noise ratio (SNR). The method presented in this work combines B-spline interpolation and Green's theorem to provide optimized quantification of blood flow and vessel wall parameters. The B-spline model provided optimal derivatives of the measured three-directional blood velocities onto the vessel contour, as required for vectorial wall shear stress (WSS) computation. Eight planes distributed along the entire thoracic aorta were evaluated in a 19-volunteer study using both high-spatiotemporal-resolution planar two-dimensional (2D)-CINE-PC ( approximately 1.4 x 1.4 mm(2)/24.4 ms) and lower-resolution 3D-CINE-PC ( approximately 2.8 x 1.6 x 3 mm(3)/48.6 ms) with three-directional velocity encoding. Synthetic data, error propagation, and interindividual, intermodality, and interobserver variability were used to evaluate the reliability and reproducibility of the method. While the impact of MR measurement noise was only minor, the limited resolution of PC-MRI introduced systematic WSS underestimations. In vivo data demonstrated close agreement for flow and WSS between 2D- and 3D-CINE-PC as well as observers, and confirmed the reliability of the method. WSS analysis along the aorta revealed the presence of a circumferential WSS component accounting for 10-20%. Initial results in a patient with atherosclerosis suggest the potential of the method for understanding the formation and progression of cardiovascular diseases.
BackgroundThe purpose of this study was to investigate 3D flow patterns and vessel wall parameters in patients with dilated ascending aorta, age-matched subjects, and healthy volunteers.MethodsThoracic time-resolved 3D phase contrast CMR with 3-directional velocity encoding was applied to 33 patients with dilated ascending aorta (diameter ≥40 mm, age=60±16 years), 15 age-matched normal controls (diameter ≤37 mm, age=68±7.5 years) and 15 young healthy volunteers (diameter ≤30 mm, age=23±2 years). 3D blood flow was visualized and flow patterns were graded regarding presence of supra-physiologic-helix and vortex flow using a semi-quantitative 3-point grading scale. Blood flow velocities, regional wall shear stress (WSS), and oscillatory shear index (OSI) were quantified.ResultsIncidence and strength of supra-physiologic-helix and vortex flow in the ascending aorta (AAo) was significantly higher in patients with dilated AAo (16/33 and 31/33, grade 0.9±1.0 and 1.5±0.6) than in controls (2/15 and 7/15, grade 0.2 ± 0.6 and 0.6 ± 0.7, P<.05) or healthy volunteers (1/15 and 0/15, grade 0.1 ± 0.3 P<.05). Greater strength of the ascending aortic helix and vortex flow were associated with significant differences in AAo diameters (P<.05). Peak systolic WSS in the ascending aorta and aortic arch was significantly lower in patients with dilated AAo (P<.0157-.0488). AAo diameter positively correlated to time to peak systolic velocities (r=0.30-0.53, P<.04), OSI (r=0.33-0.49, P<0.02) and inversely correlated to peak systolic WSS (r=0.32-0.40, P<.03). Peak systolic WSS was significantly lower in AAo aneurysms at the right and outer curvature within the AAo and proximal arch (P<.01-.05).ConclusionsIncrease in AAo diameter is significantly correlated with the presence and strength of supra-physiologic-helix and vortex formation in the AAo, as well with decrease in systolic WSS and increase in OSI.
Purpose:To assess the distribution and regional differences of flow and vessel wall parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) in the entire thoracic aorta. Materials and Methods:Thirty-one healthy volunteers (mean age ϭ 23.7 Ϯ 3.3 years) were examined by flow-sensitive four-dimensional (4D)-MRI at 3T. For eight retrospectively positioned 2D analysis planes distributed along the thoracic aorta, flow parameters and vectorial WSS and OSI were assessed in 12 segments along the vascular circumference. Conclusion:The normal distribution of vectorial WSS and OSI in the entire thoracic aorta derived from flow-sensitive 4D-MRI data provides a reference constituting an important perquisite for the examination of patients with aortic disease. Marked regional differences in absolute WSS and OSI may help explaining why atherosclerotic lesions predominantly develop and progress at specific locations in the aorta. COMPLEX VASCULAR GEOMETRY AND PULSATILE FLOW in the human arterial system lead to regionally different flow characteristics and thus spatial and temporal changes in shear forces acting on the vessel wall. These forces can be characterized by wall shear stress (WSS) or oscillatory shear index (OSI) that play an important role in flow-mediated atherogenesis and arterial remodeling (1-3). While WSS values reported in the literature typically reflect the time-averaged shear forces acting on the vessel wall, OSI describes the existence and magnitude of WSS changes over the cardiac cycle. Recent reports stressed the importance of WSS and OSI with respect to the formation and stability of atherosclerotic plaques (4). A number of studies have shown that low WSS and high OSI represent sensitive markers for formation of plaques in the aorta, carotid, or coronary arteries (5,6). Particularly, the assessment of both WSS and OSI can help to determine the complexity of the lesions. A recent study with animal models and deliberately altered flow characteristics in the carotid arteries demonstrated the close correlation of low WSS with the development of vulnerable high-risk plaques whereas high OSI induce stable lesions (4). In addition, the effects of selected pathologies on regionally-varying WSS and OSI values have been reported (7,8).Among other methods, MRI is a feasible and extensively validated technique to derive quantitative flow information from arterial vessels (9 -12). Due to its intrinsic sensitivity to flow and the possibility to acquire true time-resolved three-dimensional (3D) data, in vivo analyses of blood-flow and derived vessel wall parameters are promising. However, earlier reports on MRbased analysis of aortic hemodynamics were either based on incomplete vascular coverage and separately acquired 2D slices (13-17), a combination of MR mea-
• Secondary blood flow patterns (helices, vortices) are commonly observed in the aorta • Secondary flow patterns predominantly depend on patient age and aortic diameter • Geometric factors show a lesser impact on blood flow patterns than age and diameter • Future analyses of flow patterns should incorporate age- and diameter dependencies.
Purpose: To evaluate the feasibility of time-resolved flowsensitive MRI for the three-dimensional (3D) visualization and quantification of normal and pathological portal venous (PV) hemodynamics. Materials and Methods:Portal venous hemodynamics were evaluated in 18 healthy volunteers and 5 patients with liver cirrhosis. ECG-and adaptive respiratory navigator gated flow-sensitive 4D MRI (time-resolved 3D MRI with three-directional velocity encoding) was performed on a 3 Tesla MR system (TRIO, Siemens, Germany). Qualitative flow analysis was achieved using 3D streamlines and time-resolved particle traces originating from seven emitter planes precisely placed at anatomical landmarks in the PV system. Quantitative analysis included retrospective extraction of regional peak and mean velocities and vessel area. Results were compared with standard 2D flow-sensitive MRI and to the reference standard Doppler ultrasound.Results: Qualitative flow analysis was successfully used in the entire PV system. Venous hemodynamics in all major branches in 17 of 18 volunteers and 3 of 5 patients were reliably depicted with good interobserver agreement (kappa ¼ 0.62). Quantitative analysis revealed no significant differences and moderate agreement for peak velocities between 3D MR and 2D MRI (r ¼ 0.46) and Doppler ultrasound (US) (r ¼ 0.35) and for mean velocities between 3D and 2D MRI (r ¼ 0.41). The PV area was significantly (P < 0.01) higher in 3D and 2D MRI compared with US. Conclusion:We successfully applied 3D MR velocity mapping in the PV system, providing a detailed qualitative and quantitative analysis of normal and pathological hemodynamics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.