The purpose of this study was to assess the impact of the COVID-19 pandemic on orthopedic and trauma surgery in private practices and hospitals in Germany. Design In this cross-sectional study, an online-based anonymous survey was conducted from April 2th to April 16 th 2020. Setting The survey was conducted among 15.0000 of 18.000 orthopedic and trauma surgeons in Germany, both in private practices and hospitals. Participants All members of the German Society of Orthopedic and Trauma Surgery (DGOU) and the Professional Association for Orthopedic and Trauma Surgery (BVOU). were invited by email to participate in the survey. Main outcome measures Out of 50 questions 42 were designed to enquire a certain dimension of the pandemic impact and contribute to one of six indices, namely "Preparedness", "Resources", "Reduction", "Informedness", "Concern", and "Depletion". Data was analyzed in multiple stepwise regression, aiming to identify those factors that independently influenced the indices. Results 858 orthopedic and trauma surgeons participated in the survey throughout Germany. In the multiple regression analysis, being employed at a hospital was identified as an independent
Introduction Due to the current COVID-19 pandemic, the German Health Ministry has issued restrictions applying to the field of orthopaedics and trauma surgery. Besides postponement of elective surgeries, outpatient consultations have been drastically reduced. Parallel to these developments, an increase in telemedical consultations has reflected efforts to provide sufficient patient care. This study aims to evaluate the feasibility of a clinical examination of the hip joint and pelvis by way of a telemedical consultation. Materials and Methods Twenty-nine patients of a German university clinic were recruited and assessed in both telemedical and conventional examinations. Agreement between the two examinations was then assessed, and connections between the observed agreement and patient-specific factors such as age, BMI and ASA classification were investigated. Results The inspections agreed closely with a mean Cohenʼs kappa of 0.76 ± 0.37. Palpation showed adequate agreement with a mean Cohenʼs kappa of 0.38 ± 0.19. Function showed good agreement with a mean Cohenʼs kappa of 0.61 ± 0.26 and range of motion showed adequate agreement with a mean Cohenʼs kappa of 0.36 ± 0.19. A significant positive correlation was observed between the number of deviations in the different examinations and age (p = 0.05), and a significant positive correlation was shown between the number of non-feasible examinations and age (p < 0.01), BMI (p < 0.01) and ASA classification score (p < 0.01). Discussion Inspection and function can be reliably evaluated, whereas the significance of palpation, provocation and measurement of range of motion is limited. The small sample size puts limitations on the significance of a statistically relevant correlation between patient-specific factors such as age, BMI and ASA classification score and valid and successful implementation of a telemedical examination. The authors recommend targeted patient selection. If, however, patients are being evaluated who are very old (> 75 years), obese (BMI > 30) or with multiple comorbidities (ASA 3 and above), caution is advised. Large, prospective studies are needed in the future to fully validate telemedical consultations in the fields of orthopaedics and trauma surgery. Conclusion A telemedical examination of the hip joint and pelvis can be performed with certain limitations. Patient-specific factors such as age, BMI, and extent of comorbidities appear to have a relevant impact on validity and execution of the examination. Patients with multiple comorbidities (ASA 3 and above), advanced age (> 75 years) or obesity (BMI > 30) should, whenever possible, be examined in a conventional outpatient setting.
Background In times of a pandemic threat, such as COVID-19, and the need for reduced direct doctor-patient contact, internet-based telemedicine has attracted more and more attention as a surrogate service. Suspending the diagnosis and treatment of non-virus related diseases for longer periods of time is not a viable option since this would only exacerbate problems on the patient and national level. The need for alternative treatment modalities increased rather quickly. So far, telemedical applications have mainly focused on teleradiological diagnosis, follow-up and monitoring of psychiatric and internal diseases, as well as geriatric patient care. As far as these authors are aware, orthopaedic physical examination of the knee joint, including trauma work-up, has not been the subject of any studies to date. This feasibility study explores how video consultation can be designed and implemented in the context of history taking and physical examination in knee joint complaints. Material and Method 21 patient actors (PA) with simulated complaints of the knee joint were examined individually for each diagnosis, first via video consultation and then directly by a specialist (SP). One PA group has a medical background, the other was made up of laypersons. The time was measured for both types of consultation. The physician documented the detected symptoms, the quality of implementation of the self-examination steps, and the derived diagnosis on an assessment form. After completion of both consultation sessions, the PAs were handed a questionnaire on the respective examination modality. Results With the video consultation the examination lasted 8.63 (± 2.5) minutes on average and with the regular consultation in person 5.63 (± 1.7) minutes (p < 0.001). For the group with medical background the examination lasted 7.67 (± 1.4) minutes on average, while for the lay group the video consultation took 9.7 (± 3.1) minutes (p = 0.049). With increased age, the video consultation was prolonged (p = 0.032; r = 0.47). The mean value for self-examination of leg axis, gait pattern and degrees of freedom was 9.32 (± 0.4) of 10 points. The following functional tests resulted in lower mean values (points): Payr 7.2 (± 2.3), Merke 5.9 (± 2.8), no-touch Lachmann 6.4 (± 2.7), gravity sign-recurvatum 6.7 (± 2.4). The mean grade by the PAs for the feasibility of self-examination was 2.43 (± 0.98) out of 5 points. Conclusion The video consultation for musculoskeletal complaints of the knee joint allows exploratory remote examination and helps to minimise the number of patients in hospitals and practices. It takes longer for the physician to perform and does not permit functional testing for ligament injuries of the knee joint. In its present form, telemedical examination is not able to fully replace personal consultation.
Tantalum (Ta) is gaining attention as a biomaterial in bone tissue engineering. Although the clinical advantage of Ta-based implants for primary and revision total joint replacement (TJA) has been well documented, few studies investigated the effect of wear products of Ta implants on peri-implant cells, and their potential contribution to aseptic implant loosening. This study is aimed at examining the cytotoxicity, oxidative stress, and proinflammatory potential of Ta and TiO2 nanoparticles (NPs) on macrophages in vitro. NPs were characterized using scanning electron microscopy, dynamic light scattering, and energy-dispersive X-ray. To test the NP-mediated cellular response in macrophages, THP-1-derived macrophages were challenged with both NPs, and cytotoxicity was analyzed using CCK-8 and LDH assays. Flow cytometry was used to investigate particle uptake and their internalization routes. NP-mediated oxidative stress was investigated by measuring the production of reactive oxygen species, and their proinflammatory potential was determined by quantifying the production of TNFα and IL-1β in cell culture supernatants using ELISA. We found that both Ta and TiO2 NPs were taken up through actin-dependent phagocytosis, although TiO2 NPs did also show some involvement of macropinocytosis and clathrin-mediated endocytosis. Ta NPs caused no apparent toxicity, while TiO2 NPs demonstrated significant cytotoxicity at a concentration of over 100μg/mL at 24 h. Ta NPs induced negligible ROS generation and proinflammatory cytokines (TNFα, IL-1β) in macrophages. In contrast, TiO2 NPs markedly induced these effects in a dose-dependent manner. Our findings indicate that Ta NPs are inert, nontoxic, and noninflammatory. Therefore, Ta could be considered an excellent biomaterial in primary and revision joint arthroplasty implants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.