Background: This study evaluated the clinical significance of cell population data (CPD) parameters obtained on Sysmex XN-9000 in septic patients admitted to intensive care unit (ICU) and stratified according to liver function.
Methods:The study population consisted in 84 patients, 44 of whom did not develop sepsis (NS), whereas the remaining 40 developed sepsis (SE) (n=24) or septic shock (SS) (n=16). Two hundred ostensibly healthy blood donors [healthy subjects (HS)], undergoing routine blood testing before a regular blood donation, were studied. Conclusions: This study suggested that some novel CPD parameters (namely NE-SFL and MO-X) may provide useful information for diagnosis and management of sepsis.
BC-6800-BF offers rapid and accurate counts in clinically relevant concentration ranges, replacing LM for most samples. However, in samples with abnormal cell counts or with abnormal white blood cell differential scattergrams the need to microscopic review for a correct clinical outcome remains.
Flow cytometry is widely used in many laboratories for automated nucleated cell counts and their differentiation in body fluids. The implementation of new reflex testing rules on these automated instruments could open new frontiers in laboratory workflow, improving characterization of body fluids and clinical diagnosis and decreasing costs. Ascitic (150) and pleural (33) fluids were collected and assessed by XE-5000 and optical microscopy. Cell counts performed with the methods showed a Pearson's correlation of 0.98 (p < 0.0001), Passing-Bablok regression y = 0.99x + 2.44, and bias of 32.3. In ascitic fluids, the best diagnostic performance was found for polymorphonuclear and neutrophil counts on XE-5000, which exhibited areas under the curve (AUCs) 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. In pleural fluids the best diagnostic performance was found for polymorphonuclear percent parameter, which displayed 0.97 (p < 0.0001). Specific reflex test rules based on these parameters were characterized by 92% diagnostic concordance, 1.00 sensitivity, and 0.84 specificity with optical microscopy. The application of a set of reflex testing rules may improve the diagnostic performance of XE-5000, increasing its reliability for routine automated cell count in body fluids. We acknowledge that further studies should be planned to validate our findings according to clinical data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.