Consistency of δ 13 C measurements can be improved 39-47% by anchoring the δ 13 C scale with two isotopic reference materials differing substantially in 13 C/ 12 C. It is recommended that δ 13 C values of both organic and inorganic materials be measured and expressed relative to VPDB (Vienna Peedee belemnite) on a scale normalized by assigning consensus values of-46.6‰ to L-SVEC lithium carbonate and +1.95‰ to NBS 19 calcium carbonate. Uncertainties of other reference material values on this scale are improved by factors up to two or more, and the values of some have been notably shifted: the δ 13 C of NBS 22 oil is-30.03‰.
A method for isotope ratio analysis of water samples is described comprising an on-line high-temperature reduction technique in a helium carrier gas. Using a gas-tight syringe, injection of 0.5 to 1 microL sample is made through a heated septum into a glassy carbon reactor at temperatures in excess of 1300 degrees C. More than 150 injections can be made per day and both isotope ratios of interest, delta2H and delta18O, can be measured with the same setup. The technique has the capability to transfer high-precision stable isotope ratio analysis of water samples from a specialized to a routine laboratory task compatible with other common techniques (automated injection for GC, LC, etc.). Experiments with an emphasis on the reactor design were made in two different laboratories using two different commercially available high-temperature elemental analyser (EA) systems. In the Jena TC/EA unit, sample-to-sample memory (single injection) has been reduced to approximately 1% and high precision of about 0.1 per thousand for delta18O and < 1 per thousand for delta2H has been achieved by a redesign of the glassy carbon reactor and by redirecting the gas flow of the commercial TC/EA unit. With the modified reactor, the contact of water vapour with surfaces other than glassy carbon is avoided completely. The carrier gas is introduced at the bottom of the reactor thereby flushing the outer tube compartment of the tube-in-tube assembly before entering the active heart of the reactor.With the Leipzig high-temperature reactor (HTP) similar precision was obtained with a minor modification (electropolishing) of the injector metal sleeve. With this system, the temperature dependence of the reaction has been studied between 1100 and 1450 degrees C. Complete yield and constant isotope ratio information has been observed only for temperatures above 1325 degrees C. For temperatures above 1300 degrees C the reactor produces an increasing amount of CO background from reaction of glass carbon with the ceramic tube. This limits the usable temperature to a maximum of 1450 degrees C. Relevant gas permeation through the Al2O3 walls has not been detected up to 1600 degrees C.
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125 per thousand, an artificially enriched reference water (delta(18)O of +78.91 per thousand) and two barium sulfates (one depleted and one enriched in (18)O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference material delta(18)O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 +/- 0.36 per thousand USGS 35 sodium nitrate+56.81 +/- 0.31 per thousand IAEA-NO-3 potassium nitrate+25.32 +/- 0.29 per thousand IAEA-601 benzoic acid+23.14 +/- 0.19 per thousand IAEA-SO-5 barium sulfate+12.13 +/- 0.33 per thousand NBS 127 barium sulfate+8.59 +/- 0.26 per thousand VSMOW2 water 0 per thousand IAEA-600 caffeine-3.48 +/- 0.53 per thousand IAEA-SO-6 barium sulfate-11.35 +/- 0.31 per thousand USGS 34 potassium nitrate-27.78 +/- 0.37 per thousand SLAP water-55.5 per thousand The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for delta(18)O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (delta(18)O) of nitrates, sulfates, or organic material should explicitly state in their reports the delta(18)O values of two or more internationally distributed nitrates (USGS 34, IAEA-NO-3, and USGS 35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the delta(18)O values at a later time should it become necessary.The high-temperature reduction technique for analyzing delta(18)O and delta(2)H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.
An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ 2 H VSMOW-SLAP values from-210.8 to +397.0 mUr or ‰, for δ 13 C VPDB-LSVEC from-40.81 to +0.49 mUr, and for δ 15 N Air from-5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C 16 nalkanes, n-C 20-fatty acid methyl esters (FAMEs), glycines, and L-valines, together with polyethylene powder and string, one n-C 17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2 H-enriched vacuum oil. Eleven laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic calibrations against international primary measurement standards. The use of reference waters in silver tubes allowed direct calibration of δ 2 H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Due to exchangeable hydrogen, amino acid RMs currently are recommended only for carbon-and nitrogen-isotope measurements. Some amino acids contain 13 C and carbon-bound organic 2 Henrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Common to all these methods is that they require relatively high amounts of sample material, the conversion takes place in vacuo, and the reactions do not always lead to a single oxygen-bearing product, necessitating a second reaction step to convert other oxygen-containing products to CO 2 .A prerequisite for an on-line technique for d 18 O measurement is a fast and quantitative conversion of the sample oxygen to a single gaseous product. To produce CO or CO 2 as a measuring gas for the isotope ratio mass spectrometer (IRMS) during a carbon reduction reaction, a reagent providing carbon and reduction equivalents is needed. Although the ratio between CO and CO 2 in a static system is according to the Boudouard equilibrium 99:1 in the presence of carbon at temperatures above 1000°C, even higher temperatures are necessary in dynamic systems. 29In a previously described on-line system for d18 O and d 15 N measurement of nitrate, 30,31 samples were converted at 1200°C with graphite, but the main product was still CO 2 , accompanied by small amounts of CO, probably due to the construction of the heating device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.