Many different types of microelectrodes have been developed for use as a direct Brain-Machine Interface (BMI) to chronically recording single neuron action potentials from ensembles of neurons. Unfortunately, the recordings from these microelectrode devices are not consistent and often last for only a few weeks. For most microelectrode types, the loss of these recordings is not due to failure of the electrodes but most likely due to damage to surrounding tissue that results in the formation of nonconductive glial-scar. Since the extracellular matrix consists of nanostructured microtubules, we have postulated that neurons may prefer a more complex surface structure than the smooth surface typical of thin-film microelectrodes. We, therefore, investigated the suitability of a nano-porous silicon surface layer to increase the biocompatibility of our thin film ceramic-insulated multisite electrodes. In-vitro testing demonstrated, for the first time, decreased adhesion of astrocytes and increased extension of neurites from pheochromocytoma cells on porous silicon surfaces compared to smooth silicon sufaces. Moreover, nano-porous surfaces were more biocompatible than macroporous surfaces. Collectively, these results support our hypothesis that nano-porous silicon may be an ideal material to improve biocompatibility of chronically implanted microelectrodes. We next developed a method to apply nano-porous surfaces to ceramic insulated, thin-film, microelectrodes and tested them in vivo. Chronic testing demonstrated that the nano-porous surface modification did not alter the electrical properties of the recording sites and did not interfere with proper functioning of the microelectrodes in vivo.
Objectives: To measure the diagnostic accuracy, timeliness, and ease of use of Ceribell rapid response electroencephalography. We assessed physicians’ diagnostic assessments and treatment plans before and after rapid response electroencephalography assessment. Primary outcomes were changes in physicians’ diagnostic and therapeutic decision making and their confidence in these decisions based on the use of the rapid response electroencephalography system. Secondary outcomes were time to electroencephalography, setup time, ease of use, and quality of electroencephalography data. Design: Prospective multicenter nonrandomized observational study. Setting: ICUs in five academic hospitals in the United States. Subjects: Patients with encephalopathy suspected of having nonconvulsive seizures and physicians evaluating these patients. Interventions: Physician bedside assessment of sonified electroencephalography (30 s from each hemisphere) and visual electroencephalography (60 s) using rapid response electroencephalography. Measurements and Main Results: Physicians (29 fellows or residents, eight attending neurologists) evaluated 181 ICU patients; complete clinical and electroencephalography data were available in 164 patients (average 58.6 ± 18.7 yr old, 45% females). Relying on rapid response electroencephalography information at the bedside improved the sensitivity (95% CI) of physicians’ seizure diagnosis from 77.8% (40.0%, 97.2%) to 100% (66.4%, 100%) and the specificity (95% CI) of their diagnosis from 63.9% (55.8%, 71.4%) to 89% (83.0%, 93.5%). Physicians’ confidence in their own diagnosis and treatment plan were also improved. Time to electroencephalography (median [interquartile range]) was 5 minutes (4–10 min) with rapid response electroencephalography while the conventional electroencephalography was delayed by several hours (median [interquartile range] delay = 239 minutes [134–471 min] [p < 0.0001 using Wilcoxon signed rank test]). The device was rated as easy to use (mean ± sd: 4.7 ± 0.6 [1 = difficult, 5 = easy]) and was without serious adverse effects. Conclusions: Rapid response electroencephalography enabled timely and more accurate assessment of patients in the critical care setting. The use of rapid response electroencephalography may be clinically beneficial in the assessment of patients with high suspicion for nonconvulsive seizures and status epilepticus.
Objective Race/ethnic differences in carotid arterial function and structure exist among those with cerebrovascular disease, but whether differences persist among healthy populations is unknown. Our objective was to investigate differences in carotid artery diameter and stiffness between race/ethnic groups, and examine whether these race/ethnic differences were age-dependent. Methods Carotid diameters were assessed by B-mode ultrasound among 1536 participants from the Northern Manhattan Study (NOMAS), and carotid stiffness metrics were calculated. We used multivariable linear regression models to determine the relationship between race/ethnicity and both carotid arterial stiffness and carotid diastolic diameter. Results Mean participant age was 70 ± 9 years (Hispanics=68 ± 8, blacks=72 ± 9, and whites=74 ± 9, p<0.0001). Mean DDIAM was 6.2 ± 1.0mm (Hispanics=6.2 ± 0.9mm, blacks=6.3 ± 1.0mm, and whites=6.3 ± 1.0mm, p<0.005) and mean STIFF was 8.7 ± 6.3 (Hispanics=8.5 ± 5.7, blacks=9.2 ± 6.2 and whites=8.9 ± 6.9, p<0.02). In a model that adjusted for sociodemographics and vascular risk factors including hypertension, diabetes, dislipidemia, renal function, physical acticity and a history of known coronary artery diseases; age was positively associated with greater DDIAM in Hispanics (p<0.0001) but not among blacks or whites. Older age was associated with greater stiffness among Hispanics (p<0.0001) and blacks (p<0.003), but not among whites. Conclusions We found race/ethnic differences in the association between age and arterial stiffness and diameter, including age-dependent arterial dilation observed in Hispanics that was not observed among blacks or whites.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.