We have created a long-lived (≈40 s) persistent current in a toroidal Bose-Einstein condensate held in an all-optical trap. A repulsive optical barrier across one side of the torus creates a tunable weak link in the condensate circuit, which can affect the current around the loop. Superflow stops abruptly at a barrier strength such that the local flow velocity at the barrier exceeds a critical velocity. The measured critical velocity is consistent with dissipation due to the creation of vortex-antivortex pairs. This system is the first realization of an elementary closed-loop atom circuit.
Gas modulation refractometry (GAMOR) is a methodology that can mitigate fluctuations and drifts in refractometry. This can open up for the use of non-conventional cavity spacer materials. In this paper, we report a dual-cavity system based on Invar that shows better precision for assessment of pressure than a similar system based on Zerodur. This refractometer shows for empty cavity measurements, up to 10 4 s, a white noise response (for N 2 ) of 3 mPa s 1 / 2 . At 4303 Pa, the system has a minimum Allan deviation of 0.34 mPa (0.08 ppm) and a long-term stability (24 h) of 0.7 mPa. This shows that the GAMOR methodology allows for the use of alternative cavity materials.
The authors report on the realization of a novel methodology for refractometry—GAs modulation refractometry (GAMOR)—that decreases the influence of drifts in Fabry Perot cavity refractometry. The instrumentation is based on a dual Fabry-Perot cavity refractometer in which the beat frequency between the light fields locked to two different cavities, one measurement and one reference cavity, is measured. The GAMOR methodology comprises a process in which the measurement cavity sequentially is filled and evacuated while the reference cavity is constantly evacuated. By performing beat frequency measurements both before and after the finite-pressure measurement, zero point references are periodically created. This opens up for high precision refractometry under nontemperature-stabilized conditions. A first version of an instrumentation based on the GAMOR methodology has been realized and its basic performance has been scrutinized. The refractometer consists of a Zerodur cavity-block and tunable narrow linewidth fiber lasers operating within the C34 communication channel (i.e., around 1.55 μm) at which there are a multitude of fiber coupled off-the-shelf optical, electro-optic, and acousto-optic components. The system is fully computer controlled, which implies it can perform unattended gas assessments over any foreseeable length of time. When applied to a system with no active temperature stabilization, the GAMOR methodology has demonstrated a 3 orders of magnitude improvement of the precision with respect to conventional static detection. When referenced to a dead weight pressure scale the instrumentation has demonstrated assessment of pressures in the kilo-Pascal range (4303 and 7226 Pa) limited by white noise with standard deviations in the 3.2N−1/2–3.5N−1/2 mPa range, where N is the number of measurement cycles (each being 100 s long). For short measurement times (up to around 103 s), the system exhibits a (1σ) total relative precision of 0.7 (0.5) ppm for assessment of pressures in the 4 kPa region and 0.5 (0.4) ppm for pressures around 7 kPa, where the numbers in parentheses represent the part of the total noise that has been attributed to the refractometer. As long as the measurement procedure is performed over short time scales, the inherent properties of the GAMOR methodology allow for high precision assessments by the use of instrumentation that is not actively temperature stabilized or systems that are affected by outgassing or leaks. They also open up for a variety of applications within metrology; e.g., transfer of calibration and characterization of pressure gauges, including piston gauges.
We present the scientific motivation for future space tests of the equivalence principle, and in particular the universality of free fall, at the 10− 17 level or better. Two possible mission scenarios, one based on quantum technologies, the other on electrostatic accelerometers, that could reach that goal are briefly discussed. This publication is a White Paper written in the context of the Voyage 2050 ESA Call for White Papers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.