BackgroundThe aim of this prospective, randomized, single-blinded clinical trial was to compare the incidence of chronic pain after laparoscopic transabdominal preperitoneal hernia repair (TAPP) using a 35-g/m2 titanized polypropylene mesh and a 16-g/m2 titanized polypropylene mesh. The reported incidence of chronic pain in patients who underwent laparoscopic hernia repair is a serious problem. The techniques of dissection, mesh fixation, and the mesh material used have all been identified as being part of the problem. Excellent biocompatibility through a unique combination of a lightweight open porous polypropylene mesh covered with a covalent-bonded titanium layer has been claimed. The aim of this study was to find out whether the titanium surface alone or the difference in material load between the two available meshes influences clinical outcomes.MethodsThree hundred eighty patients with 466 inguinal hernias were operated on between 2002 and 2006 with the laparoscopic transabdominal preperitoneal (TAPP) technique. Mesh fixation with staples was carried out routinely. After the dissection was completed just prior to the implantation of the mesh, patients were randomized into two groups. In Group A, 250 (53.6%) inguinal hernias were repaired with a 35-g/m2 titanized polypropylene mesh, and in Group B, 216 (46.4%) inguinal hernias were repaired with a 16-g/m2 titanized polypropylene mesh. The primary outcome was chronic pain 3 years after surgery. The degree of pain was determined using a visual analog scale (VAS) with a range from 0 to 10. The secondary outcome was the rate of recurrence.ResultsThe postoperative period of observation was at least 3 years for every patient. In both groups, 90% of the patients could be questioned and examined clinically: in Group A (Light), 5.3% of the patients and in Group B (Extralight), 1.5% of the patients suffered from chronic pain. Chronic pain was significantly more common in Group A than in Group B (p = 0.037). There was no difference with respect to the rate of recurrence: for Group A it was 3.1% and for Group B it was 2.6% (p = 0.724).ConclusionsChronic pain is not very common in patients who have had their inguinal hernias repaired with titanium-covered polypropylene mesh. Reducing the material load from 35 to 16 g/m2 seems to further improve the biocompatibility of these meshes, thus improving the clinical outcome by reducing chronic pain to a rare event. The role of staples in causing chronic pain following inguinal hernia repair may be overestimated. There was no evidence supporting the notion that the use of the 16-g/m2 titanized meshes is associated with increased recurrence rates.
is a potentially life-threatening complication with no reliable noninvasive method of early detection.OBJECTIVE To evaluate the diagnostic accuracy of neck circumference measurement for early detection of postoperative hemorrhage after thyroidectomy. DESIGN, SETTING, AND PARTICIPANTSThis diagnostic accuracy study at an academic teaching hospital used a prospective cohort of patients undergoing thyroid surgery from November 1, 2015, to January 31, 2018 (group 1), and a retrospective cohort of patients undergoing the same surgery from January 1, 2020, to September 30, 2021 (group 2). We performed repeated perioperative neck circumference measurements to evaluate the association of increased neck circumference with postthyroidectomy hemorrhage among patients at risk for hemorrhage. MAIN OUTCOMES AND MEASURESThe primary end point was the diagnostic value of neck circumference measurement for detection of postthyroidectomy hemorrhage. Additionally, data on demographic information and risk factors for postthyroidectomy hemorrhage were examined. Data analyses were performed from November 1, 2021, to January 5, 2022. RESULTSThe prospective cohort (group 1) comprised 60 patients (45 [75%] women) with a mean (SD) age of 52.2 (13.5) years; those who experienced a postthyroidectomy hemorrhage had a mean (SD) age of 57.4 (9.0) years. The retrospective cohort (group 2) comprised 353 patients (258 [73%] women) with a mean (SD) age of 55.3 (14.1) years; patients who experienced a postthyroidectomy hemorrhage had a mean (SD) age of 62.2 (10.0) years. In group 1, postoperative neck circumference increased by a median (range) of 5.0 (4.0 to 7.0) cm in patients with hemorrhage, and only 1.0 (−2.5 to 4.0) cm in patients with no postoperative bleeding (difference in the medians, 4.0 cm [95% CI, 3.0 to 5.5 cm]; effect size, 3.74 [95% CI, 2.6 to 4.9]). Defining a 7% or greater increase in neck circumference as the cutoff value for detecting postthyroidectomy hemorrhage showed a diagnostic sensitivity and specificity of 1.0 (95% CI, 0.48 to 1.0) and 0.86 (95% CI, 0.71 to 0.92), respectively. The retrospective validation also showed a difference in median (range) increase of postoperative neck circumference between patients with hemorrhage and those without-3.0 (0 to 6.0) cm vs 0.0 (−6.0 to 5.0) cm (difference in medians, 3.8 cm [95% CI, 3.0 to 4.9]; effect size, 1.63 [95% CI, 0.96 to 2.3]). Considering 12 false-positive and 332 correct-negative results, the diagnostic tool showed a sensitivity of 0.89 (95% CI, 0.51 to 0.99) and a specificity of 0.97 (95% CI, 0.94 to 0.98). CONCLUSIONS AND RELEVANCEThe findings of this diagnostic accuracy study suggest that neck circumference measurement is a feasible and easy-to-use diagnostic tool for routine clinical care to detect postthyroidectomy hemorrhage. A 7% or greater increase over the postoperative baseline neck circumference seems to be a reliable threshold for detecting postthyroidectomy hemorrhage. Neck circumference measurement should be used in combination with surveillance of clinical s...
This is the first pilot study to consider continuous pressure measurement to be a potential tool for early detection of a postoperative rebleeding in thyroid surgery. In the strictest sense, postoperative intra-cervical pressure at rest ranges from subatmospheric to 7 mmHg. The elevation of pressure in case of a rebleeding up to 36 mmHg differs dramatically from normal postoperative pressure. The collected data will warrant further validation to be able to recommend threshold values for an early treatment decisions in rebleeding.
Hemithyroidectomy by the dorsal approach is feasible. It is a single surgeon, single port, gasless unilateral endoscopic technique with the option to go bilateral.
To support the global restart of elective surgery, data from an international prospective cohort study of 8492 patients (69 countries) was analysed using artificial intelligence (machine learning techniques) to develop a predictive score for mortality in surgical patients with SARS-CoV-2. We found that patient rather than operation factors were the best predictors and used these to create the COVIDsurg Mortality Score (https://covidsurgrisk.app). Our data demonstrates that it is safe to restart a wide range of surgical services for selected patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.