F irst introduced to clinical practice in 1980,1 the implantable cardioverter-defibrillator (ICD) improves survival in patients at high risk for sudden cardiac death. [2][3][4][5] Randomized, multicenter studies have shown a relative risk reduction in total mortality of up to 54% and an arrhythmic mortality reduction of 50% to 70%. Offsetting this mortality benefit, however, are significant acute and chronic morbidities associated with the use of transvenous leads.6-9 Procedure-related transvenous lead complications include major events such as lead dislodgement, pneumothorax, cardiac perforation, pericardial effusion, and cardiac tamponade. Chronic transvenous lead complications include systemic infections as well as insulation breaches and conductor coil breaks, which can cause inappropriate shocks and physical trauma to the heart and may render ICD therapy unavailable. The lead is the most common failure mechanism for a transvenous ICD system, and patients often outlive the useful life of the lead. 9-11 Editorial see p 938 Clinical Perspective on p 953The long-term complications associated with the transvenous ICD leads have been a rationale to develop a totally subcutaneous ICD (S-ICD). The S-ICD System (Cameron Health/Boston Scientific) senses, detects, and treats malignant ventricular tachycardia (VT)/ventricular fibrillation (VF) but leaves the heart and vasculature untouched. The subcutaneous pulse generator and electrode are placed extrathoracically, and no part of the system is exposed to most of the risks associated Background-The most frequent complications associated with implantable cardioverter-defibrillators (ICDs) involve the transvenous leads. A subcutaneous implantable cardioverter-defibrillator (S-ICD) has been developed as an alternative system. This study evaluated the safety and effectiveness of the S-ICD System (Cameron Health/Boston Scientific) for the treatment of life-threatening ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation). Methods and Results-This prospective, nonrandomized, multicenter trial included adult patients with a standard indication for an ICD, who neither required pacing nor had documented pace-terminable ventricular tachycardia. The primary safety end point was the 180-day S-ICD System complication-free rate compared with a prespecified performance goal of 79%. The primary effectiveness end point was the induced ventricular fibrillation conversion rate compared with a prespecified performance goal of 88%, with success defined as 2 consecutive ventricular fibrillation conversions of 4 attempts. Detection and conversion of spontaneous episodes were also evaluated. Device implantation was attempted in 321 of 330 enrolled patients, and 314 patients underwent successful implantation. The cohort was followed for a mean duration of 11 months. The study population was 74% male with a mean age of 52±16 years and mean left ventricular ejection fraction of 36±16%. A previous transvenous ICD had been implanted in 13%. Both primary end points were met: Th...
BACKGROUNDThe subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODSWe conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTSA total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONSIn patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to devicerelated complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.
Background: The Subcutaneous ICD (S-ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, less left ventricular dysfunction and received more inappropriate shocks (IAS) than in typical transvenous (TV)-ICD trials. The UNTOUCHED trial was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. Methods: Primary prevention patients with left ventricular ejection fraction (LVEF) ≤ 35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥ 250 beats per minute (bpm) and morphology discrimination for rates ≥200 and < 250 bpm. Patients were followed for 18 months. The primary endpoint was the IAS free rate compared to a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study. Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of endpoints. Results: S-ICD implant was attempted in 1116 patients and 1111 patients were included in post-implant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% women, 23.4% black race, 53.5% with ischemic heart disease, 87.7% with symptomatic heart failure and a mean LVEF of 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (Lower confidence limit LCL 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the three-incision technique, no history of atrial fibrillation, and ischemic etiology. The 18-month all cause shock free rate was 90.6% (LCL 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication free rate at 18 months was 92.7%. Conclusions: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of co-morbidities in comparison to earlier S-ICD trials. The inappropriate shock rate (3.1% at one year) is the lowest reported for the S-ICD and lower than many TV ICD studies using contemporary programming to reduce IAS. Clinical Trial Registration: URL https://clinicaltrials.gov Unique Identifier NCT02433379
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.