The extraordinary small size of NPs makes them difficult to detect and quantify once distributed in a material or biological system. We present a simple and straightforward method for the direct proton beam activation of synthetic or commercially available aluminum oxide NPs (Al2O3 NPs) via the 16O(p,α)13N nuclear reaction in order to assess their biological fate using positron emission tomography (PET). The radiolabeling of the NPs does not alter their surface or structural properties as demonstrated by TEM, DLS, and ζ-potential measurements. The incorporation of radioactive 13N atoms in the Al2O3 NPs allowed the study of the biodistribution of the metal oxide NPs in rats after intravenous administration via PET. Despite the short half-life of 13N (9.97 min), the accumulation of NPs in different organs could be measured during the first 68 min after administration. The percentage amount of radioactivity per organ was calculated to evaluate the relative amount of NPs per organ. This simple and robust activation strategy can be applied to any synthetic or commercially available metal oxide particle.
In vitro experiments have shown the great potential of magnetic nanocarriers for multimodal imaging diagnosis and non-invasive therapies. However, their extensive clinical application is still jeopardized by a fast retention in the reticuloendothelial system (RES). The other issue that restrains their potential performance is slow degradation and excretion, which increases their risks of toxicity. We report a promising case in which multicore iron oxide nanoparticles coated with a poly(4-vinylpyridine) polyethylene glycol copolymer show low RES retention and high urinary excretion, as confirmed by single photon emission computerized tomography (SPECT), gamma counting, magnetic resonance imaging (MRI) and electron microscopy (EM) biodistribution studies. These iron oxide-copolymer nanoparticles have a high PEG density in their coating which may be responsible for this effect. Moreover, they show a clear negative contrast in the MR imaging of the kidneys. These nanoparticles with an average hydrodynamic diameter of approximately 20 nm were nevertheless able to cross the glomerulus wall which has an effective pore size of approximately 6 nm. A transmission electron microscopy inspection of kidney tissue revealed the presence of iron containing nanoparticle clusters in proximal tubule cells. This therefore makes them exceptionally useful as magnetic nanocarriers and as new MRI contrast agents for the kidneys.
The determination of nanoparticle (NP) stability and degradation in vivo is essential for the accurate evaluation of NP biodistribution in medical applications and for understanding their toxicological effects. Such determination is particularly challenging because NPs are extremely difficult to detect and quantify once distributed in a biological system. Radiolabelling with positron or gamma emitters and subsequent imaging studies using positron emission tomography (PET) or single-photon emission computerised tomography (SPECT) are some of the few valid alternatives. However, NPs that degrade or radionuclides that detach or are released from the NPs can cause artefact. Here, submicron-sized poly(lactide-coglycolide) nanoparticles (PLGA-NPs) stabilised with bovine serum albumin (BSA) were dual radiolabelled using gamma emitters with different energy spectra incorporated into the core and coating. To label the core, 111 In-doped iron oxide NPs were encapsulated inside PLGA-NPs during NP preparation, and the BSA coating was labelled by electrophilic substitution using 125 I. After intravenous administration into rats, energy-discriminant SPECT resolved each radioisotope independently. Imaging revealed different fates for the core and coating, with a fraction of the two radionuclides co-localising in the liver and lungs for long periods of time after administration, suggesting that NPs are stable in these organs. Organ harvesting followed by gamma counting corroborated the SPECT results. The general methodology reported here represents an excellent alternative for visualising the degradation process of multi-labelled NPs in vivo and can be extended to a wide range of engineered NPs. 20009,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.