The autograft principle results in postoperative long-term survival comparable with that of the age- and gender-matched general population and reoperation rates within the 1%/patient-year boundaries and should be considered in young, active patients who want to avoid the shortcomings of conventional prostheses.
Hybrid aortic repair using the FET in acute DeBakey type I aortic dissection does not elevate the perioperative risk of mortality and provides excellent aortic remodelling with low distal re-intervention rate in mid-term follow-up.
The intraprocedural data were excellent and comparable in the groups, but postoperative outcomes were better in the MECC group. Thus MECC is preferable to CECC even for minimally invasive valve procedures. These findings strongly support a combined strategy of minimally invasive valve operations and minimally invasive extracorporeal circulation.
Background
After tricuspid valve (TV) surgery due to tricuspid regurgitation (TR), patients needing a permanent pacemaker often receive an epicardial lead implantation. This may result in delayed recovery from open‐chest surgery and increased postoperative risk. Leadless pacemaker (LPM) implantation may represent a valuable option.
Methods and Results
A total of 14 consecutive patients underwent LPM implantation (Micra Transcatheter Pacing System, Medtronic, Minneapolis, MN) early after TV surgery. The pacing indication in those patients was atrial fibrillation with a slow atrio‐ventricular (AV) conduction or atrial fibrillation and a concomitant AV block III. Three patients already had a pacemaker prior to surgery, which was explanted during TV repair. Three patients received a valve replacement with a bioprosthesis, while the remaining eight patients received a TV repair. All procedural data and device measurements during and after LPM implantation were recorded. Transthoracic echocardiography was performed prior and post LPM implantation, showing no changes in TV or bioprosthesis performance. The device measurements were within an adequate range: threshold: 0.83 ± 0.34 V @ 0.24 ± 0 ms, impedance: 480 ± 58.88 ohm, and R‐wave: 10.10 ± 3.60 mV. LPM implantation was successful in all patients with a mean procedural time of 32 ± 11.8 minutes, fluoroscopy time of 3.71 ± 3.15 minutes, and dose‐area product of 536.67 ± 811.26 cGy/m2.
Conclusions
Implantation of an LPM early after TV surgery is a feasible option. LPM implantation does not affect TV or bioprosthesis performance in transthoracic echocardiography.
scite is a Brooklyn-based startup that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.