This research was to conduct a pilot study for two consecutive days in order to assess fine particulate matter (PM2.5) exposure of an entire population in a community. We aimed to construct a surveillance system by analyzing the observed spatio-temporal variation of exposure. Guro-gu in Seoul, South Korea, was divided into 2,204 scale grids of 100 m each. Hourly exposure concentrations of PM2.5 were modeled by the inverse distance weighted method, using 24 sensor-based air monitoring instruments and the indoor-to-outdoor concentration ratio. Population distribution was assessed using mobile phone network data and indoor residential rates, according to sex and age over time. Exposure concentration, population distribution, and population exposure were visualized to present spatio-temporal variation. The PM2.5 exposure of the entire population of Guro-gu was calculated by population-weighted average exposure concentration. The average concentration of outdoor PM2.5 was 42.1 µg/m3, which was lower than the value of the beta attenuation monitor measured by fixed monitoring station. Indoor concentration was estimated using an indoor-to-outdoor PM2.5 concentration ratio of 0.747. The population-weighted average exposure concentration of PM2.5 was 32.4 µg/m3. Thirty-one percent of the population exceeded the Korean Atmospheric Environmental Standard for PM2.5 over a 24 h average period. The results of this study can be used in a long-term aggregate and cumulative PM2.5 exposure assessment, and as a basis for policy decisions on public health management among policymakers and stakeholders.
The 2014 Time-Use Survey of Statistics Korea revealed that office workers are increasingly spending more than eight hours at work. This study conducted an exposure assessment for office workers in Korea. Indoor and outdoor air pollutants were measured in offices. A self-administered questionnaire was employed to determine work information, indoor air quality (IAQ) awareness, and subjective symptoms for 328 workers. Indoor air concentrations for measured air pollutants were below IAQ guideline values. The average concentrations of target air pollutants did not show significant differences except for benzene, which had relatively a higher concentration in national industrial complexes. The indoor benzene, ethylbenzene, and acetaldehyde concentrations were higher in offices where workers were having dry eye, ophthalmitis, and headache symptoms. This study provides reference values to manage IAQ in offices, suggesting that if the benzene concentration exceeds 4.23 μg/m3 in offices, it could cause dry eye symptoms. Considering the increasing working hours for office workers and health effects, workers' exposure to indoor pollutants should be reduced. In addition, the IAQ was heavily influenced by outdoor air levels and various indoor sources. Therefore, in areas with relatively high air pollution, greater monitoring and management is required considering the influence of outdoor air quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.