Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007, medical uses represent the largest source of exposure to the U.S. population. Most physicians have difficulty assessing the magnitude of exposure or potential risk. Effective dose provides an approximate indicator of potential detriment from ionizing radiation and should be used as one parameter in evaluating the appropriateness of examinations involving ionizing radiation. The purpose of this review is to provide a compilation of effective doses for radiologic and nuclear medicine procedures. Standard radiographic examinations have average effective doses that vary by over a factor of 1000 (0.01-10 mSv). Computed tomographic examinations tend to be in a more narrow range but have relatively high average effective doses (approximately 2-20 mSv), and average effective doses for interventional procedures usually range from 5-70 mSv. Average effective dose for most nuclear medicine procedures varies between 0.3 and 20 mSv. These doses can be compared with the average annual effective dose from background radiation of about 3 mSv.
Background-The use of computed tomographic (CT) scans in the United States (US) has increased more than 3-fold since 1993 to approximately 70 million scans annually. Despite the great medical benefits, there is concern about the potential radiation-related cancer risk. We conducted detailed estimates of the future cancer risks from current CT scan use in the US according to age, sex, and scan type. Methods-Risk models based on the National Research Council's "Biological Effects of Ionizing Radiation" report and organ-specific radiation doses derived from a national survey were used to estimate age-specific cancer risks for each scan type. These models were combined with age-and sex-specific scan frequencies for the US in 2007 obtained from survey and insurance claims data. We estimated the mean number of radiation-related incident cancers with 95% uncertainty limits (UL) using Monte Carlo simulations. Results-Overall, we estimated that approximately 29 000 (95% UL, 15 000-45 000) future cancers could be related to CT scans performed in the US in 2007. The largest contributions were from scans of the abdomen and pelvis (n = 14 000) (95% UL, 6900-25 000), chest (n = 4100) (95% UL, 1900-8100), and head (n = 4000) (95% UL, 1100-8700), as well as from chest CT angiography (n = 2700) (95% UL, 1300-5000). One-third of the projected cancers were due to scans performed at the ages of 35 to 54 years compared with 15% due to scans performed at ages younger than 18 years, and 66% were in females. Conclusions-These detailed estimates highlight several areas of CT scan use that make large contributions to the total cancer risk, including several scan types and age groups with a high frequency of use or scans involving relatively high doses, in which risk-reduction efforts may be warranted. The use of computed tomographic (CT) scans in the United States (US) has increased more than 3-fold since 1993 to approximately 70 million scans annually. 1 While CT scans can
The U.S. National Council on Radiation Protection and Measurements and United Nations Scientific Committee on Effects of Atomic Radiation each conducted respective assessments of all radiation sources in the United States and worldwide. The goal of this article is to summarize and combine the results of these two publicly available surveys and to compare the results with historical information. In the United States in 2006, about 377 million diagnostic and interventional radiologic examinations and 18 million nuclear medicine examinations were performed. The United States accounts for about 12% of radiologic procedures and about one-half of nuclear medicine procedures performed worldwide. In the United States, the frequency of diagnostic radiologic examinations has increased almost 10-fold (1950-2006). The U.S. per-capita annual effective dose from medical procedures has increased about sixfold (0.5 mSv [1980] to 3.0 mSv [2006]). Worldwide estimates for 2000-2007 indicate that 3.6 billion medical procedures with ionizing radiation (3.1 billion diagnostic radiologic, 0.5 billion dental, and 37 million nuclear medicine examinations) are performed annually. Worldwide, the average annual per-capita effective dose from medicine (about 0.6 mSv of the total 3.0 mSv received from all sources) has approximately doubled in the past 10-15 years.
The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate representation of the complex human anatomy and has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. A disadvantage to the NURBS basis of the XCAT, however, is that the mathematical complexity of the surfaces makes the calculation of line integrals through the phantom difficult. They have to be calculated using iterative procedures; therefore, the calculation of CT projections is much slower than for simpler mathematical phantoms. To overcome this limitation, the authors used efficient ray tracing techniques from computer graphics, to develop a fast analytic projection algorithm to accurately calculate CT projections directly from the surface definition of the XCAT phantom given parameters defining the CT scanner and geometry. Using this tool, realistic high-resolution 3D and 4D projection images can be simulated and reconstructed from the XCAT within a reasonable amount of time. In comparison with other simulators with geometrically defined organs, the XCAT-based algorithm was found to be only three times slower in generating a projection data set of the same anatomical structures using a single 3.2 GHz processor. To overcome this decrease in speed would, therefore, only require running the projection algorithm in parallel over three processors. With the ever decreasing cost of computers and the rise of faster processors and multi-processor systems and clusters, this slowdown is basically inconsequential, especially given the vast improvement the XCAT offers in terms of realism and the ability to generate 3D and 4D data from anatomically diverse patients. As such, the authors conclude that the efficient XCAT-based CT simulator developed in this work will have applications in a broad range of CT imaging research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.