New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C_{3}F_{8} located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C_{3}F_{8} exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10^{-41} cm^{2} for a 30-GeV c^{-2} WIMP, more than 1 order of magnitude improvement from previous PICO results.
We report results of an electron-beam-dump search for neutral particles with masses in the range 1 to 15 MeV and lifetimes r between 10 ~1 4 and 10 -10 s. No evidence was found for such an object. We rule out the existence of any 1.8-MeV pseudoscalar boson with r > 8.2 x 10 ~1 5 s and an absorption cross section in matter less than 1 mb per nucleon, and exclude r> 1 x 10 ~1 4 s were its cross section to equal 50 mb per nucleon. In conjunction with measurements of the electron's anomalous magnetic moment, this experiment shows that the narrow positron peaks observed in heavy-ion collisions at the Gessellschaft fur Schwerionenforschung are not due to an elementary pseudoscalar.
A search for short-lived neutral particles which decay to electron-positron pairs has been carried out using a beam of 275-GeV electrons incident on an instrumented tungsten beam dump. The experiment was sensitive to particles up to 10 MeV/c 2 in mass and down to 4x 10" l6 sec in lifetime.
Final results are reported from operation of the PICO-60 C3F8 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 × 10 −41 cm 2 for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
Bubble chambers were the dominant technology used for particle detection in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on a new application for these devices. We operated an ultraclean, room-temperature bubble chamber containing 1.5 kilograms of superheated CF3I, a target maximally sensitive to spin-dependent and -independent weakly interacting massive particle (WIMP) couplings. An extreme intrinsic insensitivity to the backgrounds that commonly limit direct searches for dark matter was measured in this device under operating conditions leading to the detection of low-energy nuclear recoils like those expected from WIMPs. Improved limits on the spin-dependent WIMP-proton scattering cross section were extracted during our experiments, excluding this type of coupling as a possible explanation for a recent claim of particle dark-matter detection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.