Background:Technical aspects of the correct placement of medial support locking screws in the locking plate for proximal humerus fractures remain incompletely understood. This study was to evaluate the clinical relationship between the number of medial support screws and the maintenance of fracture reduction after locked plating of proximal humerus fractures.Methods:We retrospectively evaluated 181 patients who had been surgically treated for proximal humeral fractures (PHFs) with a locking plate between September 2007 and June 2013. All cases were then subdivided into one of four groups as follows: 75 patients in the medial cortical support (MCS) group, 26 patients in the medial multiscrew support (MMSS) group, 29 patients in the medial single screw support (MSSS) group, and 51 patients in the no medial support (NMS) group. Clinical and radiographic evaluations included the Constant-Murley score (CM), visual analogue scale (VAS), complications, and revision surgeries. The neck-shaft angle (NSA) was measured in a true anteroposterior radiograph immediately postoperation and at final follow-up. One-way analysis of variance or Kruskal-Wallis test was used for statistical analysis of measurement data, and Chi-square test or Fisher's exact test was used for categorical data.Results:The mean postoperative NSAs were 133.46° ± 6.01°, 132.39° ± 7.77°, 135.17° ± 10.15°, and 132.41° ± 7.16° in the MCS, MMSS, MSSS, and NMS groups, respectively, and no significant differences were found (F = 1.02, P = 0.387). In the final follow-up, the NSAs were 132.79° ± 6.02°, 130.19° ± 9.25°, 131.28° ± 12.85°, and 127.35° ± 8.50° in the MCS, MMSS, MSSS, and NMS groups, respectively (F = 4.40, P = 0.008). There were marked differences in the NSA at the final follow-up between the MCS and NMS groups (P = 0.004). The median (interquartile range [IQR]) NSA losses were 0.0° (0.0–1.0)°, 1.3° (0.0–3.1)°, 1.5° (1.0–5.2)°, and 4.0° (1.2–7.1)° in the MCS, MMSS, MSSS, and NMS groups, respectively (H = 60.66, P < 0.001). There were marked differences in NSA loss between the MCS and the other three groups (MCS vs. MMSS, Z = 3.16, P = 0.002; MCS vs. MSSS, Z = 4.78, P < 0.001; and MCS vs. NMS, Z = 7.34, P < 0.001). There was also significantly less NSA loss observed in the MMSS group compared to the NMS group (Z = −3.16, P = 0.002). However, there were no significant differences between the MMSS and MSSS groups (Z = −1.65, P = 0.225) or the MSSS and NMS groups (Z = −1.21, P = 0.099). The average CM scores were 81.35 ± 9.79, 78.04 ± 8.97, 72.76 ± 10.98, and 67.33 ± 12.31 points in the MCS, MMSS, MSSS, and NMS groups, respectively (F = 18.68, P < 0.001). The rates of excellent and good CM scores were 86.67%, 80.77%, 65.52%, and 43.14% in the MCS, MMSS, MSSS, and NMS groups, respectively (χ2= 29.25, P < 0.001). The median (IQR) VAS scores were 1 (0–2), 1 (0–2), 2 (1–3), and 3 (1–5) points in the MCS, MMSS, MSSS, and NMS groups, respectively (H = 27.80, P < 0.001). Functional recovery was markedly better and VAS values were lower in the MCS and MMSS groups...
Closed reduction and internal fixation with antegrade intramedullary nails is a feasible and effective treatment for displaced fifth metacarpal neck fractures (FMNFs). The present study aimed to compare clinical and radiological outcomes in patients with displaced FMNFs after treatment with single or dual antegrade elastic intramedullary nails (AEIMNs). Thirty-three patients were treated with a single 2.0 mm AEIMN and 34 patients were treated with two 1.5 mm AEIMNs. Clinical and radiological outcomes included grip strength, active range of motion (ROM), active flexion and extension of the fifth metacarpophalangeal (MCP) joint, dorsal angulation loss, and metacarpal shortening of the fifth metacarpal at 12 months after treatment. No significant difference was observed between the two groups with respect to grip strength, ROM or flexion of the fifth MCP joint. The average values of dorsal angulation loss, metacarpal shortening, and extension of the fifth MCP joint of the dual nails group were better than those of the single nail group (dorsal angulation loss, 2.79 ± 1.93° vs. 4.05 ± 1.59°, P = 0.009; metacarpal shortening, 1.66 ± 0.80 mm vs. 2.12 ± 0.88 mm, P = 0.028; extension of the fifth MCP joint, 7.71 ± 4.43° vs. 4.82 ± 4.09°, P = 0.012). In conclusion, dual AEIMNs fixation provided better MCP extension and radiological outcomes than single AEIMN fixation.
Background: Although various implants exist for the fixation of isolated greater tuberosity fractures, few implants are specifically designed for such fractures. The purpose of this study was to investigate the clinical and radiologic outcomes of open reduction-internal fixation with a low-profile anatomic locking plate for comminuted greater tuberosity fractures of the proximal humerus. Methods: From November 2012 to February 2018, 24 patients with displaced and comminuted isolated greater tuberosity fractures were treated with the new low-profile anatomic locking plate. To determine clinical outcomes, we evaluated active range of motion; the visual analog scale pain score; the Constant-Murley score; the Disabilities of the Arm, Shoulder and Hand score; radiographs; and complications. Results: In all cases, a mean follow-up period of 29.3 months (range, 18-48 months) was completed. All patients achieved bone union with a mean healing time of 11.3 weeks (range, 8-16 weeks). The mean Constant-Murley score was 91.1 points (range, 69-100 points), with a rate of good to excellent results of 95.8%. The average Disabilities of the Arm, Shoulder and Hand score was 9.9 points (range, 2-25 points), and the mean visual analog scale pain score was 1.1 points (range, 0-4 points). Mean active forward flexion, abduction, external rotation, and internal rotation (level) were 157 , 152 , and 40 , and T11, respectively. Postoperatively, 1 patient had persistent shoulder stiffness, and 1 patient had recurrence of shoulder dislocation because of a falling injury during badminton. No serious complications such as subacromial impingement, malunion, nonunion, loss of reduction, or implant failure occurred. Conclusions: The new low-profile anatomic locking plate was useful for the treatment of comminuted isolated greater tuberosity fractures as it provided reliable stability and satisfactory radiographic and functional results. The described technique is a simple and effective method and provides a new reliable option for the treatment of isolated greater tuberosity fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.