PET/CT allows accurate analysis of anatomical/morphological and metabolic/functional correlations of SPN, providing useful data for identifying and locating the disease, for differentiating between malignant and benign nodules and for establishing the aggressiveness and degree of vascularity of pulmonary lesions. Therefore, partly in view of the considerable reduction in time and cost of the single examinations, we believe that PET/CT will gain an increasingly dominant role in the diagnostic and therapeutic approach to lung cancer, especially in the preclinical phase.
Ultrasound (US) still represents the mainstay of scrotal imaging. However, contrast-enhanced ultrasound (CEUS) is a relatively novel, but increasingly utilized diagnostic modality. In consequence, we performed a systematic review (SR) and pooled meta-analysis to investigate the diagnostic performance of CEUS in the evaluation of testicular masses (TM). A SR up to June 2021 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The diagnostic performance of CEUS was evaluated basing on two different endpoints: neoplastic vs. non-neoplastic and malignant vs. benign TM. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) from eligible studies were pooled and summary receiver operating characteristic (SROC) curves were constructed for each endpoint. Overall, six qualified studies were deemed suitable for this meta-analysis. Diagnostic performance of CEUS showed an accuracy of 0.96 in detecting neoplastic masses (sensitivity of 0.89, PPV of 0.85, specificity of 0.62, and NPV of 0.69) and an accuracy of 0.96 in detecting malignant masses (sensitivity of 0.86, PPV of 0.73, specificity of 0.87, and NPV of 0.91). Taken together, CEUS may represent a promising minimally invasive diagnostic tool for characterization of TM, since it allows clinicians to identify neoplastic lesions and exclude malignant tumor.
Ultrasound (US) is a highly sensitive imaging tool in the detection of renal masses. However, the detection rate of small renal masses (SRMs) (<4 cm) is still limited. In this scenario, contrast-enhanced ultrasound (CEUS) is a relatively novel, but increasingly utilized, diagnostic modality which aims to increase the overall diagnostic ability in the identification of SRMs. In consequence, we performed a systematic review (SR) and pooled meta-analysis to investigate the diagnostic performance of CEUS in the evaluation of SRMs confirmed by pathology. A SR up to April 2022 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The diagnostic performance of CEUS was evaluated basing on malignant vs. benign SMRs. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) from eligible studies were pooled, and summary receiver operating characteristic (SROC) curves were constructed for each endpoint. Overall, five qualified studies were deemed suitable for this meta-analysis. Finally, diagnostic performance of CEUS showed an accuracy of 0.93 in detecting malignant masses (sensitivity of 0.94, PPV of 0.95, specificity of 0.78, and NPV of 0.73). Taken together, CEUS may represent a promising minimally invasive diagnostic tool for characterization of SMRs, since it allows clinicians to identify malignant lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.