Background Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. Methods A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally. Results No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. Conclusion PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA.
Background We report the ability to extend lung preservation up to 24 hours (24H) by using autologous whole donor blood circulating within an ex vivo lung perfusion (EVLP) system. This approach facilitates donor lung reconditioning in a model of extended normothermic EVLP. We analyzed comparative responses to cellular and acellular perfusates to identify these benefits. Methods Twelve pairs of swine lungs were retrieved after cardiac arrest and studied for 24H on the Organ Care System (OCS) Lung EVLP platform. Three groups (n=4 each) were differentiated by perfusate: (1) isolated red blood cells (RBCs) (current clinical standard for OCS); (2) whole blood (WB); and (3) acellular buffered dextran-albumin solution (BDAS, analogous to STEEN solution). Results Only the RBC and WB groups met clinical standards for transplantation at 8 hours; our primary analysis at 24H focused on perfusion with WB versus RBC. The WB perfusate was superior (vs. RBC) for maintaining stability of all monitored parameters, including the following mean 24H measures: pulmonary artery pressure (6.8 vs. 9.0 mmHg), reservoir volume replacement (85 vs. 1607 mL), and PaO2:FiO2 ratio (541 vs. 223). Acellular perfusion was limited to 6 hours on the OCS system due to prohibitively high vascular resistance, edema, and worsening compliance. Conclusions The use of an autologous whole donor blood perfusate allowed 24H of preservation without functional deterioration and was superior to both RBC and BDAS for extended lung preservation in a swine model using OCS Lung. This finding represents a potentially significant advance in donor lung preservation and reconditioning.
Background: There is no effective method to predict paravalvular regurgitation prior to transcatheter aortic valve replacement (TAVR). Methods: We retrospectively analyzed pre-TAVR computed tomography (CT) scans of 20 patients who underwent TAVR for severe, calcific aortic stenosis and subsequently printed 3-dimensional (3D) aortic root models of each patient. Models were printed using Ninjaflex thermoplastic polyurethane (TPU) (Ninjatek Manheim, PA) and TPU 95A (Ultimaker, Netherlands) on Ultimaker 3 Extended 3D printer (Ultimaker, Netherlands). The models were implanted at nominal pressure with same sized Sapien balloon-expandable frames (Edwards Lifesciences, CA) as received in-vivo. Ex-vivo implanted TAVR models (eTAVR) were scanned using Siemens SOMATOM flash dual source CT (Siemens, Malvern, PA) and then analyzed with Mimics software (Materialize NV, Leuven, Belgium) to evaluate relative stent appositions. eTAVR were then compared to post-TAVR echocardiograms for each patient to assess for correlations of identified and predicted paravalvular leak (PVL) locations. Results: A total of 20 patients (70% male) were included in this study. The median age was 77.5 (74-83.5) years. Ten patients were characterized to elicit mild (9/10) or moderate (1/10) PVL, and 10 patients presented no PVL. In patients with echocardiographic PVL, eTAVR 3D model analyses correctly identified the site of PVL in 8/10 cases. In patients without echocardiographic PVL, eTAVR 3D model analyses correctly predicted the lack of PVL in 9/10 cases. Conclusion: 3D printing may help predict the potential locations of associated PVL post-TAVR, which may have implications for optimizing valve selection and sizing.
Background: Pulsed field ablation (PFA) is a novel energy modality for treatment of cardiac arrhythmias. The impact of electrode-tissue proximity on lesion formation by PFA has not been conclusively assessed. The objective of this investigation was to evaluate the effects of electrode-tissue proximity on cardiac lesion formation with a biphasic, bipolar PFA system. Methods: PFA was delivered on the ventricular epicardial surface in an isolated porcine heart model (n=8) via a 4-electrode prototype catheter. An offset tool was designed to control the distance between electrodes and target tissue; deliveries were placed 0 mm (0 mm offset), 2 mm (2 mm offset), and 4 mm away from the tissue (4 mm offset). Lesions were assessed using tetrazolium chloride staining. Numerical models for the experimental setup with and without the offset tool validated and supported results. Results: Cardiac lesion dimensions decreased proportional to the distance between epicardial surface and electrodes. Lesion depth-averaged 4.3±0.4 mm, 2.7±0.4 mm, and 1.3±0.4 mm for the 0, 2, and 4 mm and lesion width averaged 9.4±1.1 mm, 7.5±0.8 mm and 5.8±1.4 mm for the 0, 2, and 4 mm offset distances, respectively. Numerical modeling matched ex vivo results well and predicted lesion creation with and without the offset tool. Conclusions: Using a biphasic, bipolar PFA system resulted in cardiac lesions even in the 0 mm offset distance case. The relationship between lesion depth and offset distance was linear, and the deepest lesions were created with 0 mm offset distance, that is, with electrodes in contact with tissue. Therefore, close electrode-tissue proximity increases the likelihood of achieving transmural lesions by maximizing the electric field penetration into the target tissue.
Introduction: Contact force has been used to titrate lesion formation for radiofrequency ablation. Pulsed field ablation (PFA) is a field-based ablation technology for which limited evidence on the impact of contact force on lesion size is available.Methods: Porcine hearts (n = 6) were perfused using a modified Langendorff set-up.A prototype focal PFA catheter attached to a force gauge was held perpendicular to the epicardium and lowered until contact was made. Contact force was recorded during each PFA delivery. Matured lesions were cross-sectioned, stained, and the lesion dimensions measured.Results: A total of 82 lesions were evaluated with contact forces between 1.3 and 48.6 g. Mean lesion depth was 4.8 ± 0.9 mm (standard deviation), mean lesion width was 9.1 ± 1.3 mm, and mean lesion volume was 217.0 ± 96.6 mm 3 . Linear regression curves showed an increase of only 0.01 mm in depth (depth = 0.01 × contact force + 4.41, R 2 = 0.05), 0.03 mm in width (width = 0.03 × contact force + 8.26, R 2 = 0.13) for each additional gram of contact force, and 2.20 mm 3 in volume (volume = 2.20 × contact force + 162, R 2 = 0.10). Conclusion:Increasing contact force using a bipolar, biphasic focal PFA system has minimal effects on acute lesion dimensions in an isolated porcine heart model and achieving tissue contact is more important than the force with which that contact is made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.