Our institute has constructed a new treatment facility for carbon ion scanning beam therapy. The first clinical trials were successfully completed at the end of November 2011. To evaluate patient setup accuracy, positional errors between the reference Computed Tomography (CT) scan and final patient setup images were calculated using 2D-3D registration software. Eleven patients with tumors of the head and neck, prostate and pelvis receiving carbon ion scanning beam treatment participated. The patient setup process takes orthogonal X-ray flat panel detector (FPD) images and the therapists adjust the patient table position in six degrees of freedom to register the reference position by manual or auto- (or both) registration functions. We calculated residual positional errors with the 2D-3D auto-registration function using the final patient setup orthogonal FPD images and treatment planning CT data. Residual error averaged over all patients in each fraction decreased from the initial to the last treatment fraction [1.09 mm/0.76° (averaged in the 1st and 2nd fractions) to 0.77 mm/0.61° (averaged in the 15th and 16th fractions)]. 2D-3D registration calculation time was 8.0 s on average throughout the treatment course. Residual errors in translation and rotation averaged over all patients as a function of date decreased with the passage of time (1.6 mm/1.2° in May 2011 to 0.4 mm/0.2° in December 2011). This retrospective residual positional error analysis shows that the accuracy of patient setup during the first clinical trials of carbon ion beam scanning therapy was good and improved with increasing therapist experience.
Registration of patient anatomical structures to the reference position is a basic part of the patient set-up procedure. Registration of anatomical structures between the site of beam entrance on the patient surface and the distal target position is particularly important. Here, to improve patient positional accuracy during set-up for particle beam treatment, we propose a new visualization methodology using digitally reconstructed radiographs (DRRs), overlaid DRRs, and evaluation of overlaid DRR images in clinical cases. The overlaid method overlays two DRR images in different colors by dividing the CT image into two CT sections at the distal edge of the target along the treatment beam direction. Since our hospital uses fixed beam ports, the treatment beam angles for this study were set at 0 and 90 degrees. The DRR calculation direction was from the X-ray tube to the imaging device, and set to 180/270 degrees and 135/225 degrees, based on the installation of our X-ray imaging system. Original and overlaid DRRs were calculated using CT data for two patients, one with a parotid gland tumor and the other with prostate cancer. The original and overlaid DRR images were compared. Since the overlaid DRR image was completely separated into two regions when the DRR calculation angle was the same as the treatment beam angle, the overlaid DRR visualization technique was able to provide rich information for aiding recognition of the relationship between anatomical structures and the target position. This method will also be useful in patient set-up procedures for fixed irradiation ports.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.