PurposeThe purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator.MethodsA risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance.ResultsThe recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test.ConclusionThis guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.
Background: While the review of radiotherapy treatment plans and charts by a medical physicist is a key component of safe, high-quality care, very few specific recommendations currently exist for this task. Aims: The goal of TG-275 is to provide practical, evidence-based recommendations on physics plan and chart review for radiation therapy. While this report is aimed mainly at medical physicists, others may benefit including dosimetrists, radiation therapists, physicians and other professionals interested in quality management. Methods: The scope of the report includes photon/electron external beam radiotherapy (EBRT), proton radiotherapy, as well as high-dose rate (HDR) brachytherapy for gynecological applications (currently the highest volume brachytherapy service in most practices). The following review time points are considered: initial review prior to treatment, weekly review, and end-of-treatment review. The Task Group takes a risk-informed approach to developing recommendations. A failure mode and effects analysis was performed to determine the highest-risk aspects of each process. In the case of photon/electron EBRT, a survey of all American Association of Physicists in Medicine (AAPM) members was also conducted to determine current practices. A draft of this report was provided to the full AAPM membership for comment through a 3-week open-comment period, and the report was revised in response to these comments.Results: The highest-risk failure modes included 112 failure modes in photon/electron EBRT initial review, 55 in weekly and end-of-treatment review, 24 for initial review specific to proton therapy, and 48 in HDR brachytherapy. A 103-question survey on current practices was released to all AAPM members who self-reported as working in the radiation oncology field. The response rate was 33%. The survey data and risk data were used to inform recommendations. Discussion: Tables of recommended checks are presented and recommendations for best practice are discussed. Suggestions to software vendors are also provided. Conclusions: TG-275 provides specific recommendations for physics plan and chart review which should enhance the safety and quality of care for patients receiving radiation treatments.
The clinical use of surface imaging has increased dramatically, with demonstrated utility for initial patient positioning, real-time motion monitoring, and beam gating in a variety of anatomical sites. The Therapy Physics Subcommittee and the Imaging for Treatment Verification Working Group of the American Association of Physicists in Medicine commissioned Task Group 302 to review the current clinical uses of surface imaging and emerging clinical applications. The specific charge of this task group was to provide technical guidelines for clinical indications of use for general positioning, breast deep-inspiration breath hold treatment, and frameless stereotactic radiosurgery. Additionally, the task group was charged with providing commissioning and on-going quality assurance (QA) requirements for surface-guided radiation therapy (SGRT) as part of a comprehensive QA program including risk assessment. Workflow considerations for other anatomic sites and for computed tomography simulation, including motion management, are also discussed. Finally, developing clinical applications, such as stereotactic body radiotherapy (SBRT) or proton radiotherapy, are presented. The recommendations made in this report, which are summarized at the end of the report, are applicable to all video-based SGRT systems available at the time of writing.
The authors conclude that the use of the projection method minimizes the sharing of MLC leaves between lesions and improves the plan quality for multilesion VMAT delivery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.