OBJECTIVE There are few prior reports of acute pelvic instrumentation failure in spinal deformity surgery. The objective of this study was to determine if a previously identified mechanism and rate of pelvic fixation failure were present across multiple institutions, and to determine risk factors for these types of failures. METHODS Thirteen academic medical centers performed a retrospective review of 18 months of consecutive adult spinal fusions extending 3 or more levels, which included new pelvic screws at the time of surgery. Acute pelvic fixation failure was defined as occurring within 6 months of the index surgery and requiring surgical revision. RESULTS Failure occurred in 37 (5%) of 779 cases and consisted of either slippage of the rods or displacement of the set screws from the screw tulip head (17 cases), screw shaft fracture (9 cases), screw loosening (9 cases), and/or resultant kyphotic fracture of the sacrum (6 cases). Revision strategies involved new pelvic fixation and/or multiple rod constructs. Six patients (16%) who underwent revision with fewer than 4 rods to the pelvis sustained a second acute failure, but no secondary failures occurred when at least 4 rods were used. In the univariate analysis, the magnitude of surgical correction was higher in the failure cohort (higher preoperative T1-pelvic angle [T1PA], presence of a 3-column osteotomy; p < 0.05). Uncorrected postoperative deformity increased failure risk (pelvic incidence–lumbar lordosis mismatch > 10°, higher postoperative T1PA; p < 0.05). Use of pelvic screws less than 8.5 mm in diameter also increased the likelihood of failure (p < 0.05). In the multivariate analysis, a larger preoperative global deformity as measured by T1PA was associated with failure, male patients were more likely to experience failure than female patients, and there was a strong association with implant manufacturer (p < 0.05). Anterior column support with an L5–S1 interbody fusion was protective against failure (p < 0.05). CONCLUSIONS Acute catastrophic failures involved large-magnitude surgical corrections and likely resulted from high mechanical strain on the pelvic instrumentation. Patients with large corrections may benefit from anterior structural support placed at the most caudal motion segment and multiple rods connecting to more than 2 pelvic fixation points. If failure occurs, salvage with a minimum of 4 rods and 4 pelvic fixation points can be successful.
Background: Minimally invasive sacroiliac (SI) joint fusion is indicated for low back pain from the SI joint that is due to degenerative sacroiliitis and/or sacroiliac joint disruption. This technique is safe and effective in relieving pain uncontrolled by nonoperative management 1 - 4 . There is some controversy, but there continues to be increasing evidence of effectiveness. Description: This procedure is performed, with the patient under general anesthesia and in the prone position, using fluoroscopy or 3-dimensional (3D) navigation such as cone-beam computed tomographic (CT) imaging. After navigation setup, a navigated probe is used to approximate the desired location of each implant and trajectory. These positions are marked on the skin, and the skin is incised. A 3 to 5-cm lateral incision is made. The gluteal fascia is bluntly dissected to the outer table of the ilium. A guide pin is passed across the SI joint and into the center of the sacrum lateral to the neural foramina, which is confirmed with imaging. This is then drilled and broached. Triangular titanium rods are placed. Typically, 3 implants are placed, 2 in S1 and 1 in S2. Multiplanar postplacement imaging of the pelvis is obtained. The wound is irrigated and closed in layers. Alternatives: Nonsurgical alternatives have been reported to include pharmacological therapies, such as nonsteroidal anti-inflammatory drugs, therapeutic SI joint blocks 5 , and physical therapy, such as core stabilization, orthotics (SI belts), and radiofrequency ablation 1 , 2 , 6 - 8 . The surgical alternative is an open anterior or posterior approach with SI joint arthrodesis. The anterior approach differs by the resection of the SI joint cartilage, the use of a plate or screws across the joint for stabilization, and the packing of bone graft to facilitate fusion 9 . These are more morbid and have a much longer recovery. Rationale: Conservative management for SI joint pain is inadequate for all patients. Having 3 of 5 positive physical examination maneuvers 7 , having confirmatory diagnostic block(s) 10 , and ruling out the hip or spine as the pain generator provide a success rate of >80%. These patients have early and sustained clinically important and significantly improved outcomes across varying measures compared with conservative treatment 1 - 4 , 11 , 12 . Expected Outcomes: Patients can expect to experience decreased pain, reduced disability, increased daily function, and improved quality of life soon after the procedure ...
OBJECTIVE Pelvic fixation enhances long constructs during deformity surgery. Subsequent loosening of iliac screws and pain at the pelvis occur in as many as 29% of patients. Concomitant sacroiliac (SI) fusion may prevent potential pain and failure. The objective of this study was to describe a novel surgical technique and a single institution’s experience using bilateral SI fusion during adult deformity surgery with S2-alar-iliac (S2AI) screws and triangular titanium rods (TTRs) placed with navigation. METHODS The authors reviewed open SI joint fusions with TTR performed between August 2019 and March 2020. All patients underwent lumbosacral fusion through a midline approach and bilateral S2AI pelvic fixation in the caudal teardrop, followed by TTR placement just proximal and cephalad to the S2AI screws using intraoperative CT imaging guidance. RESULTS Twenty-one patients were identified who received 42 TTRs, ranging in size from 7.0 × 65 mm to 7.0 × 90 mm. Three TTRs (7%) were malpositioned intraoperatively, and each was successfully repositioned during index surgery without negative sequelae. All breaches occurred in a medial and cephalad direction into the pelvis. Incremental operative time for adding TTR averaged 8 minutes and 33 seconds per implant. CONCLUSIONS Image-guided open SI joint fusion with TTR during lumbosacral fusion is technically feasible. The bony corridor for implant placement is narrower cephalad, and implants tend to deviate medially into the pelvis. Detection of malpositioned implant is aided with intraoperative CT, but this can be salvaged. A prospective randomized clinical trial is underway that will better inform the impact of this technique on patient outcomes.
OBJECTIVE Pelvic fixation with S2-alar-iliac (S2AI) screws is an established technique in adult deformity surgery. The authors’ objective was to report the incidence and risk factors for an underreported acute failure mechanism of S2AI screws. METHODS The authors retrospectively reviewed a consecutive series of ambulatory adults with fusions extending 3 or more levels, and which included S2AI screws. Acute failure of S2AI screws was defined as occurring within 6 months of the index surgery and requiring surgical revision. RESULTS Failure occurred in 6 of 125 patients (5%) and consisted of either slippage of the rods or displacement of the set screws from the S2AI tulip head, with resultant kyphotic fracture. All failures occurred within 6 weeks postoperatively. Revision with a minimum of 4 rods connecting to 4 pelvic fixation points was successful. Two of 3 (66%) patients whose revision had less fixation sustained a second failure. Patients who experienced failure were younger (56.5 years vs 65 years, p = 0.03). The magnitude of surgical correction was higher in the failure cohort (number of levels fused, change in lumbar lordosis, change in T1–pelvic angle, and change in coronal C7 vertical axis, each p < 0.05). In the multivariate analysis, younger patient age and change in lumbar lordosis were independently associated with increased failure risk (p < 0.05 for each). There was a trend toward the presence of a transitional S1–2 disc being a risk factor (OR 8.8, 95% CI 0.93–82.6). Failure incidence was the same across implant manufacturers (p = 0.3). CONCLUSIONS All failures involved large-magnitude correction and resulted from stresses that exceeded the failure loads of the set plugs in the S2AI tulip, with resultant rod displacement and kyphotic fractures. Patients with large corrections may benefit from 4 total S2AI screws at the time of the index surgery, particularly if a transitional segment is present. Salvage with a minimum of 4 rods and 4 pelvic fixation points can be successful.
Case: We present a long-term follow-up on a woman with otospondylomegaepiphyseal dysplasia (OSMED). At the age of 46 years, she is one of the oldest patients with the syndrome in the literature to date. We focus on the musculoskeletal anatomy and orthopaedic interventions over her lifetime. Conclusion: OSMED is a very rare syndrome. Arthritis and joint pains presented in her early adolescence and progressed to the point of requiring joint replacements by her 20s. Early intervention and monitoring improved the quality of life for this patient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.