Local tumor compression is the main mechanical cause of posterior interosseous nerve (PIN) palsy. The reported cases of these tumors do not include that of pigmented villonodular synovitis (PVNS). Here, we report a case of a 53-year-old male with a 9-year history of painless swelling in his left elbow and a few months of progressive weakness in his left hand. Imaging identified the mass, and histological examination of the biopsy specimens revealed PVNS. The mass was compressing the nerve at the arcade of Frohse, and we performed a complete resection of the mass. Following removal of the mass, the patient regained complete function in his left upper extremity, and no local recurrence has been detected after 2 postoperative years. The possibility of PVNS should be considered in the differential diagnosis of PIN palsy.
Background:
Despite the popularity and superiority of resorbable alloplastic materials in orbital fracture reconstruction, it is unclear whether the reconstructed wall is maintained after implant resorption. Unsintered hydroxyapatite/poly-L-lactide (u-HA/PLLA) is one such material, but it differs from conventional materials for the replacement of natural bones. This study investigated the intermediate-term safety and efficacy of u-HA/PLLA implants compared with those of implants made with other alloplastic materials.
Methods:
The authors retrospectively analyzed 240 eligible patients who underwent orbital fracture reconstruction with one alloplastic material between January of 2006 and October of 2018. Materials used for treatment were as follows: u-HA/PLLA sheet in 101 patients, u-HA/PLLA mesh in 38 patients, poly-L-lactic acid/poly-glycolic acid mesh in 47 patients, silicone sheet in 35 patients, and titanium mesh in 19 patients. Intermediate-term follow-up was performed for a median duration of 48.2 months. A chart review was performed. Postoperative complications and factors affecting them were studied. Reconstructed area deformities were assessed using computed tomography.
Results:
Postoperative complications occurred significantly more frequently in patients reconstructed with the silicone sheet than in those reconstructed with the u-HA/PLLA sheet. Deformities were found for the silicone sheet (28.6 percent) and poly-L-lactic acid/poly-glycolic acid mesh (31.9 percent). These deformity rates were significantly higher than those for the u-HA/PLLA sheet.
Conclusions:
Compared with other alloplastic materials, u-HA/PLLA has low rates of postoperative complications and reconstructed area deformities. Because of its complete absorption, clinicians should consider using u-HA/PLLA as an alloplastic material for orbital wall reconstruction.
CLINICAL QUESTION/LEVEL OF EVIDENCE:
Therapeutic, III.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.