Cardiac transplantation can be performed successfully in patients with end-stage congenital heart disease after a Glenn or Fontan procedure, with outcomes similar to transplantation for end-stage heart failure secondary to other etiologies.
Endovascular stent implantation for pulmonary artery stenosis requires the use of a long, large-bore vascular sheath to insure precise implantation without embolization or malposition. A long vascular sheath may be difficult to position and usage may be associated with vascular compromise and/or hemodynamic embarrassment, especially in infants and small children. We report a new technique for pulmonary artery endovascular stent implantation without the use of a long sheath. From December 2000 to May 2001, 10 patients underwent implantation of 13 Palmaz Corinthian premounted biliary transhepatic stents for pulmonary artery stenosis. Median age was 0.8 years (range, 0.5-18.5) and median weight was 11.8 kg (range, 4.6-65). Patient diagnoses were tetralogy of Fallot (five), double outlet right ventricle (three), branch peripheral pulmonary artery stenosis (two), single ventricle s/p cavopulmonary shunt (one), and truncus arteriosus (one). All Palmaz Corinthian stents were delivered uncovered on Cordis Opta LP balloon catheters via short sheaths (6-7 Fr); super-stiff guidewires were not always necessary. These stents, with a maximal expanded diameter of 12 mm, were placed for peripheral pulmonary artery stenosis as a definitive procedure or at the pulmonary artery bifurcation in patients who were expected to undergo future open heart surgery. The stents were initially implanted on 4, 6, or 8 mm balloon catheters and further expanded if needed. Stents were placed in the right pulmonary artery alone in three patients, left pulmonary artery alone in four patients, and side-by-side stents were implanted simultaneously in three patients. All thirteen stents were implanted successfully in the desired location without stent malposition or embolization. Mean angiographic diameter increased from 2.5 +/- 1.5 to 5.7 +/- 1.4 mm (P < 0.01) and peak systolic ejection gradients decreased from 44 +/- 22 to 14 +/- 11.6 mm Hg (P < 0.01). The uncovered delivery of the premounted Palmaz Corinthian stent allowed for precise and safe endovascular stent implantation without the hemodynamic and technical problems associated with long vascular sheath usage. This technique is useful for the palliation of proximal pulmonary artery stenosis and is effective definitive treatment for peripheral pulmonary artery stenosis in small infants and children.
The American College of Cardiology Adult Congenital and Pediatric Cardiology (ACPC) Section had attempted to create quality metrics (QM) for ambulatory pediatric practice, but limited evidence made the process difficult. The ACPC sought to develop QMs for ambulatory pediatric cardiology practice. Five areas of interest were identified, and QMs were developed in a 2-step review process. In the first step, an expert panel, using the modified RAND-UCLA methodology, rated each QM for feasibility and validity. The second step sought input from ACPC Section members; final approval was by a vote of the ACPC Council. Work groups proposed a total of 44 QMs. Thirty-one metrics passed the RAND process and, after the open comment period, the ACPC council approved 18 metrics. The project resulted in successful development of QMs in ambulatory pediatric cardiology for a range of ambulatory domains.
Epithelialization of chronic cutaneous wound is troublesome and may require use of skin/cell substitutes. Adipose-derived mesenchymal stem cells (ADMSCs) have immense potential as autologous cell source for treating wounds; they can cross the germ layer boundary of differentiation and regenerate skin. When multipotent adult stem cells are considered for skin regeneration, lineage committed keratinocytes may be beneficial to prevent undesirable post-transplantation outcome. This study hypothesized that ADMSCs may be directed to epidermal lineage in vitro on a specifically designed biomimetic and biodegradable niche. Cells were seeded on the test niche constituted with fibrin, fibronectin, gelatin, hyaluronic acid, laminin V, platelet growth factor, and epidermal growth factor in the presence of cell-specific differentiation medium (DM). The ADMSCs grown on bare tissue culture polystyrene surface in DM is designated DM-control and those grown in basal medium (BM) is the BM-control. Lineage commitment was monitored with keratinocyte-specific markers such as cytokeratin 14, cytokeratin 5, cytokeratin 19, and integrin α6 at the transcriptional/translational level. The in vitro designed biomimetic fibrin composite matrix may have potential application as cell transplantation vehicle.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.