Importance Electronic cigarette (e-cigarette) use in pregnancy has been steadily increasing and has been hyped as being a safe alternative to cigarette smoking during pregnancy. This review discloses what is currently known about e-cigarette use in pregnancy and the effects of its use on pregnancy outcomes. Objective To determine what is currently known about the prevalence of e-cigarette use in pregnancy and the effects of e-cigarette use on pregnancy and perinatal/neonatal outcomes. Evidence Acquisition A PubMed, CINAHL, and EMBASE search was undertaken using the search terms “pregnancy” OR “pregnancy complications” OR “pregnancy outcome” OR “newborn” OR “neonate” OR “birth” AND “electronic cigarettes” OR “e-cigarettes” OR “ecigarettes” OR “vaping” OR “vape.” The search was limited to the English language and between 2007 and October 12, 2017. Results The search identified 91 articles, 40 of which are the basis for this review. The prevalence of e-cigarette use is 0.6% to 15%. The amount of nicotine consumed by e-cigarette users is comparable to that consumed by cigarette smokers. Most of the animal model studies suggest a potential danger to the developing fetus primarily because of the nicotine consumed and that consumption has multiple effects on the immune system, neural development, lung function, and cardiac function. There is a widespread flawed perception that e-cigarettes are safe to use during pregnancy. Conclusions The marketing of e-cigarette use as a safer alternative to cigarette smoking has led to an increasing use even in pregnancy. The nicotine consumed by e-cigarettes is similar to that consumed by cigarette smoking. Animal studies confirm the dangers of nicotine to the developing fetus. More research needs to be done specifically assessing e-cigarette use, pregnancy, and pregnancy outcomes. Relevance The amount of nicotine consumed in cigarette smoking is similar to the amount of nicotine consumed with e-cigarettes. The effects of nicotine exposure during fetal development are well known and include effects on multiple organ systems. Target Audience Obstetricians and gynecologists, family physicians. Learning Objectives After completing this activity, the learner should be better able to determine the prevalence of e-cigarette use in pregnancy, analyze and compare the nicotine consumed with cigarette smoking versus the nicotine consumed with e-cigarette smoking, and evaluate the risk in animal studies of the consumption of nicotine on the developing fetus.
BACKGROUND: Few adequately validated patient-reported outcome measures are available, which can assess recovery profiles following childbirth. OBJECTIVE: We aimed to determine whether quantitative recovery (using the Obstetric Quality of Recovery-10 patient-reported outcome measure) was superior following vaginal delivery compared with cesarean delivery and evaluate validity, reliability, and responsiveness of this patientreported outcome measure in the obstetrical setting in the United States. STUDY DESIGN: Women recruited into this single-center observational cohort study completed the Obstetric Quality of Recovery-10 and EuroQol 5-dimension 3L patient-reported outcome measures within 72 hours of childbirth. We assessed the validity with hypothesis testing and structural validity. In hypothesis testing, the primary outcome was Obstetric Quality of Recovery-10 scores after vaginal vs cesarean delivery. Secondary outcomes were differences in Obstetric Quality of Recovery-10 scores for vaginal delivery following induction of labor vs spontaneous labor and scheduled vs unplanned cesarean delivery, correlation with clinical parameters (American Society of Anesthesiologists classification grade, body mass index, length of hospital stay, estimated blood loss, transfusion requirement, antiemetic use, and neonatal intensive care unit admission), and qualitative ranking of Obstetric Quality of Recovery-10 items for each delivery mode. Structural validity was assessed by determining the correlation of the Obstetric Quality of Recovery-10 scores with the EuroQol 5-dimension 3L and global health visual analog scale scores. Reliability was assessed using Cronbach alpha and inter-item correlation of Obstetric Quality of Recovery-10 items. Responsiveness was assessed by evaluating the change in Obstetric Quality of Recovery-10 scores over the 72-hour postpartum period. RESULTS: Data from 215 women were analyzed. In hypothesis testing, the median (interquartile range) Obstetric Quality of Recovery-10 scores were higher following vaginal delivery than cesarean delivery (86 [77e94] vs 77 [64e86], respectively; P<.001). Multivariate model demonstrated that Obstetric Quality of Recovery-10 scores were significantly lower after cesarean delivery when adjusting for American Society of Anesthesiologists classification grade, age, body mass index, and ethnicity (R¼À8.97; P<.001). Obstetric Quality of Recovery-10 scores were similar between induction of labor and spontaneous labor, and scheduled cesarean delivery and unplanned cesarean delivery. Obstetric Quality of Recovery-10 was correlated with length of hospital stay (R¼À0.248; P<.001), estimated blood loss (R¼À0.3429; P<.001), transfusion requirement (R¼À0.140; P¼.041), and antiemetic use (R¼À0.280; P<.001). The highest ranked Obstetric Quality of Recovery-10 items were ability to hold baby, feeling in control, and ability to look after personal hygiene. The lowest ranked items were pain and shivering. In structural validity, correlation of Obstetric Quality of Recovery-10 score wa...
p24 proteins comprise a family of type-I transmembrane proteins of ~24kD that are present in yeast and plants as well as metazoans ranging from Drosophila to humans. These proteins are most commonly localized to the endoplasmic reticulum (ER)-Golgi interface and are incorporated in anterograde and retrograde transport vesicles. Little is known about how disruption of p24 signaling affects individual tissue function or whole animals. Drosophila melanogaster express nine p24 genes, grouped into four subfamilies. Based upon our mRNA and protein expression data, Drosophila p24 family members are expressed in a variety of tissues. To identify functions for particular Drosophila p24 proteins, we used RNA interference (RNAi) to reduce p24 expression. Ubiquitous reduction of most p24 genes resulted in complete or partial lethality during development. We found that reducing p24 levels in adults caused defects in female fecundity (egg laying) and also reduced male fertility. We attributed reduced female fecundity to decreased neural p24 expression. These results provide the first genetic analysis of all p24 family members in a multicellular animal and indicate vital roles for Drosophila p24s in development and reproduction, implicating neural expression of p24s in the regulation of female behavior.
Objectives To identify abnormal amniotic fluid volumes (AFVs), normal volumes must be determined. Multiple statistical methods are used to define normal amniotic fluid curves; however, quantile regression (QR) is gaining favor. We reanalyzed ultrasound estimates in identifying oligohydramnios, normal fluid, and polyhydramnios using normal volumes calculated by QR. Methods Data from 506 dye‐determined or directly measured AFVs along with ultrasound estimates were analyzed. Each was classified as low, normal, or high for both the single deepest pocket (SDP) and amniotic fluid index (AFI). A weighted κ statistic was used to assess the level of agreement between the AFI and SDP compared to actual AFVs by QR. Results The overall level of agreement for the AFI was fair (κ = 0.26), and that for the SDP was slight (κ = 0.19). Although not statistically significant (P = .792), the positive predictive value to classify a low volume using the AFI was lower compared to the SDP (35% vs 43%). The positive predictive value for a high volume was higher using the AFI compared to the SDP (55% versus 31%) but not statistically significant. The missed‐call rate for high‐volume identification by the SDP versus AFI was statistically significant (odds ratio, 5.5; 95% confidence interval, 2.04–14.97). The missed‐call rate for low‐volume identification by the AFI versus SDP was not statistically significant (odds ratio, 3.3; 95% confidence interval, 0.96–11.53). Conclusions Both the AFI and SDP identify actual normal AFVs by QR, with sensitivity higher than 90%. The SDP is superior for identification of oligohydramnios, and the AFI superior for identification of polyhydramnios.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.