The review suggests that the KT-1000 knee arthrometer and the Rolimeter provide best results when testing anterior laxity at the knee, whereas the Telos device is superior for the assessment of posterior laxity.
To determine the relative risk of complications in treating ankle fractures in patients with diabetes, we compared the results of the management of displaced malleolar fractures in 26 patients with those of a matched group of non-diabetic patients, using a case-controlled study. The groups were matched for patient age, fracture type and treating surgeon. The incidence of significant complications in diabetic patients was 42.3%. By contrast, there were no complications in the matched group of non-diabetic patients. Of 19 diabetic patients treated surgically, six developed major complications including one case of malunion, one of necrosis of the wound edge requiring a flap, and two of deep sepsis. Two patients required amputation and both died. Diabetic patients with displaced ankle fractures treated non-operatively had a high incidence of loss of reduction and malunion but these caused few symptoms. In these patients, non-operative management may be preferable in view of the high risks of major complications after surgery and the acceptance of malunion by the older patient with lower demands.
The KT-1000 knee arthrometer (KT-1000) is an objective instrument to measure anterior tibial motion relative to the femur for anterior cruciate ligament (ACL) reconstruction. Four studies between 1950 and 2007 regarding validity of the KT-1000 were identified using a Medline search. One had interpretable information on sensitivities, specificities, and predictive values to validate the instrument as a diagnostic tool in patients with acute or chronic ACL injuries. Three had limitations in methodology. We suggest that the KT-1000 should be used with caution as an objective instrument. Rather, using a KT-1000 score derived by subtracting the anterior tibial motion relative to the femur of the injured knee to that of the uninjured knee may be more appropriate as a dichotomous diagnostic test with a threshold of 2 or 3 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.