An interference-resilient 60 kb/s-10 Mb/s body channel transceiver using the human body as a signal transmission medium is designed for multimedia and medical data transaction in body-area network. The body antenna effect which interferes with signals in the human body channel is examined. The body-induced interferences degrade the SIR of the signal to 22 dB in the worst case. In order to overcome the body antenna effect, a 4-channel adaptive frequency hopping scheme using the 30-120 MHz band is introduced to the body channel transceiver. A direct-switching modulator using dual frequency synthesizers and a DLL-based demodulator are proposed for 10 Mb/s FSK and the 4.2 s hopping time. The transceiver fabricated with 0.18 m CMOS withstands 28 dB SIR and its operating distance is over 1.8 m with 25 dB SIR. Its energy consumption is 0.37 nJ/b with 65 dBm sensitivity.
A multi-modal spectroscopy IC combining impedance spectroscopy (IMPS) and multi-wavelength near-infrared spectroscopy (mNIRS) is proposed for high precision non-invasive glucose level estimation. A combination of IMPS and mNIRS can compensate for the glucose estimation error to improve its accuracy. The IMPS circuit measures dielectric characteristics of the tissue using the RLC resonant frequency and the resonant impedance to estimate the glucose level. To accurately find resonant frequency, a 2-step frequency sweep sinusoidal oscillator (FSSO) is proposed: 1) 8-level coarse frequency switching (f STEP = 9.4 kHz) in 10-76 kHz, and 2) fine analog frequency sweep in the range of 18.9 kHz. During the frequency sweep, the adaptive gain control loop stabilizes the output voltage swing (400 mV p-p ). To improve accuracy of mNIRS, three wavelengths, 850 nm, 950 nm, and 1,300 nm, are used. For highly accurate glucose estimation, the measurement data of the IMPS and mNIRS are combined by an artificial neural network (ANN) in external DSP. The proposed ANN method reduces the mean absolute relative difference to 8.3% from 15% of IMPS, and 15-20% of mNIRS in 80-180 mg/dL blood glucose level. The proposed multi-modal spectroscopy IC occupies 12.5 mm 2 in a 0.18 µm 1P6M CMOS technology and dissipates a peak power of 38 mW with the maximum radiant emitting power of 12.1 mW.Index Terms-Adaptive gain control, artificial neural network, frequency sweep sinusoidal oscillator, impedance spectroscopy, near-infrared spectroscopy, non-invasive glucose monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.