The baseline data from GLORIA-AF phase 2 demonstrate that in newly diagnosed nonvalvular atrial fibrillation patients, NOAC have been highly adopted into practice, becoming more frequently prescribed than VKA in Europe and North America. Worldwide, however, a large proportion of patients remain undertreated, particularly in Asia and North America. (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients With Atrial Fibrillation [GLORIA-AF]; NCT01468701).
MPP showed a further reduction in LV dyssynchrony compared with conventional biventricular pacing. Moreover, MPP resulted in an additional improvement in LVEF and in CI, and this was translated into a higher number of acute responders to CRT.
Introduction
Conduction system pacing (CSP) has emerged as an ideal physiologic pacing strategy for patients with permanent pacing indications. We sought to evaluate the safety and feasibility of CSP in a consecutive series of unselected patients with congenital heart disease (CHD).
Methods
Consecutive patients with CHD in which CSP was attempted were included. Safety and feasibility, implant tools and electrical parameters at implant and at follow‐up were evaluated.
Results
A total of 20 patients were included (10 with a previous device). A total of 10 patients had complex forms of CHD, 9 moderate defects and 1 a simple defect. CSP was achieved in 75% of cases (10 His bundle pacing, 5 left bundle branch pacing) with left ventricular septal pacing in the remaining 5 patients. Procedure times and fluoroscopy times were prolongued (126 ± 82 min and 27 ± 30 min, respectively). Ventricular lead implant times widely varied ranging from 4 to 115 min, (mean 31 ± 28 min) and the use of multiple delivery sheaths was frequent (50%). The QRS width was reduced from 145 ± 36 ms at baseline to 116 ± 18 ms with CSP. Implant electrical parameters included: CSP pacing threshold 0.95 ± 0.65 V; R wave amplitude 9.2 ± 8.8 mV and pacing impedance 632 ± 183 Ohms, and remained stable at a median follow‐up of 478 days (interquartile range: 225–567). Systemic ventricle systolic function and NYHA class (1.50 ± 0.51 vs. 1.10 ± 0.31; p = .008) significantly improved at follow‐up. Lead revision was required in one patient at Day 4.
Conclusions
Permanent CSP is safe and feasible in patients with CHD although implant technique is complex.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.