Photoacoustic imaging (PAI) combines optical contrast with ultrasound spatial resolution and can be obtained up to a depth of a few centimeters. Hand-held PAI systems using linear array usually operate in reflection mode using a dark-field illumination scheme, where the optical fiber output is attached to both sides of the elevation plane (short-axis) of the transducer. More recently, bright-field strategies where the optical illumination is coaxial with acoustic detection have been proposed to overcome some limitations of the standard dark-field approach. In this paper, a novel multiangle long-axis lateral illumination is proposed. Monte Carlo simulations were conducted to evaluate light delivery for three different illumination schemes: bright-field, standard dark-field, and long-axis lateral illumination. Long-axis lateral illumination showed remarkable improvement in light delivery for targets with a width smaller than the transducer lateral dimension. A prototype was developed to experimentally demonstrate the feasibility of the proposed approach. In this device, the fiber bundle terminal ends are attached to both sides of the transducer’s long-axis and the illumination angle of each fiber bundle can be independently controlled. The final PA image is obtained by the coherent sum of subframes acquired using different angles. The prototype was experimentally evaluated by taking images from a phantom, a mouse abdomen, forearm, and index finger of a volunteer. The system provided light delivery enhancement taking advantage of the geometry of the target, achieving sufficient signal-to-noise ratio at clinically relevant depths.
For improved efficiency and security in heat application during hyperthermia, it is important to monitor tissue temperature during treatments. Photoacoustic (PA) pressure wave amplitude has a temperature dependence given by the Gruenesein parameter. Consequently, changes in PA signal amplitude carry information about temperature variation in tissue. Therefore, PA has been proposed as an imaging technique to monitor temperature during hyperthermia. However, no studies have compared the performance of different algorithms to generate PA-based thermal images. Methods: Here, four methods to estimate variations in PA signal amplitude for thermal image formation were investigated: peak-to-peak, integral of the modulus, autocorrelation of the maximum value, and energy of the signal. Changes in PA signal amplitude were evaluated using a 1-D window moving across the entire image. PA images were acquired for temperatures ranging from 36 o C to 41 o C using a phantom immersed in a temperature controlled thermal bath. Results: The results demonstrated that imaging processing parameters and methods involved in tracking variations in PA signal amplitude drastically affected the sensitivity and accuracy of thermal images formation. The sensitivity fluctuated more than 20% across the different methods and parameters used. After optimizing the parameters to generate the thermal images using an evolutionary genetic algorithm (GA), the percentage of pixels within the acceptable error was improved, in average, by 7.5%. Conclusion: Optimization of processing parameters using GA could increase the accuracy of measurement for this experimental setup and improve quality of PA-based thermal images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.