Titanium dioxide (TiO(2)) under ultraviolet (UV) light produces a strong oxidative effect and may therefore be used as a photocatalytic disinfectant. Although many studies on the photocatalytic inactivation of bacteria have been reported, few studies have addressed virus inactivation. In the present study, we demonstrated the inactivation of influenza virus through TiO(2) photocatalysis using TiO(2) nanoparticles immobilized on a glass plate. The influences of the UV intensity, UV irradiation time and bovine serum albumin (BSA) concentration in the viral suspensions on the inactivation kinetics were investigated. Additionally, we also determined whether the International Organization for Standardization (ISO) methodology for the evaluation of antibacterial activity of TiO(2) photocatalysis could be applied to the evaluation of antiviral activity. The viral titers were dramatically reduced by the photocatalytic reaction. Even with a low intensity of UV-A (0.01 mW cm(-2)), a viral reduction of approximately 4-log(10) was observed within a short irradiation time. The viral inactivation kinetics were associated with the exposure time, the UV intensity and the BSA concentration in virus suspensions. These results show that TiO(2) photocatalysis could be used to inactivate the influenza virus. Furthermore, a minor modification of the ISO test method for anti-bacterial effects of TiO(2) photocatalysis could be useful for the evaluation of antiviral activity.
Photocatalytically active titanium dioxide (TiO 2 ) is widely used as a self-cleaning and self-disinfecting material in many applications to keep environments biologically clean. Several studies on the inactivation of bacteria and viruses by photocatalytic reactions have also been reported; however, only few studies evaluated the spectrum of the microbicidal activity with photocatalysis for various species. There is a need to confirm the expected OPEN ACCESSCatalysts 2013, 3 311 effectiveness of disinfection by photocatalysis against multidrug-resistant bacteria and viruses. In this study, microbicidal activity of photocatalysis was evaluated by comparing the inactivation of various species of bacteria and viruses when their suspensions were dropped on the surface of TiO 2 -coated glass. Gram-positive bacteria, e.g., methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus faecalis, and penicillin-resistant Streptococcus pneumoniae, were easily inactivated by photocatalysis, whereas some gram-negative bacteria, e.g., Escherichia coli and multidrug-resistant Pseudomonas aeruginosa, were gradually inactivated by photocatalysis. Influenza virus, an enveloped virus, was significantly inactivated by photocatalysis compared with feline calicivirus, a non-enveloped virus. The effectiveness of microbicidal activity by photocatalysis may depend on the surface structure. However, they are effectively inactivated by photocatalysis on the surface of TiO 2 -coated glass. Our data emphasize that effective cleaning and disinfection by photocatalysis in nosocomial settings prevents pathogen transmission.
A total of 480 serum samples from donors including 384 children up to 10 years of age were examined by the hemagglutination-inhibition (HI) (4x2", n~l) were 4.90 and 4.30. About 50% of the children had acquired antibodies against BK virus by 3 years of age and against ]C virus by 6 years of age. These results indicate that dual latent infections with both viruses are common, although independent infections with either virus are predominant in the human population.
Objectives The maintenance of infectivity of influenza viruses on the surfaces of personal protective equipment and clothing is an important factor in terms of controlling viral cross-infection in the environment and preventing contact infection. The aim of this study was to determine if laboratory-grown influenza A (H1N1) virus maintained infectivity on the surfaces of personal protective equipment and clothing used in healthcare settings. Methods Influenza A virus (0.5 mL) was deposited on the surface of a rubber glove, an N95 particulate respirator, a surgical mask made of non-woven fabric, a gown made of Dupont Tyvek, a coated wooden desk, and stainless steel. Each sample was left for 1, 8, and 24 h, and hemagglutination (HA) and 50% tissue culture infective dose (TCID 50 )/mL were measured. Results The HA titer of this influenza A virus did not decrease in any of the materials tested even after 24 h. The infectivity of influenza A virus measured by TCID 50 was maintained for 8 h on the surface of all materials, with the exception of the rubber glove for which virus infectivity was maintained for 24 h. Conclusions Our results indicate that the replacement/ renewal of personal protective equipment and clothing by healthcare professionals in cases of exposure to secretions and droplets containing viruses spread by patients is an appropriate procedure to prevent cross-infection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.