The occurrence of particulate lead in drinking water deserves increased scrutiny. This is especially true because models of human exposure to lead, sampling protocols, analytical methods, and environmental assessments are often based on the presumed dominance of soluble lead in drinking water. Recent cases of childhood lead poisoning were tied to solder particles that detached from the plumbing and contaminated the potable water supply. In cases such as these, common samplehandling procedures can “miss” particulate lead present in water samples. In some instances, the actual amount of lead present in drinking water samples may be five times higher than that obtained using approved protocols. The presence of chloride, warmer temperature, and lower pH in the human stomach may render a significant fraction of this “missed” particulate lead as bioavailable when ingested.
In April 2014, the drinking water source in Flint, Michigan was switched from Lake Huron water with phosphate inhibitors to Flint River water without corrosion inhibitors. The absence of corrosion control and use of a more corrosive source increased lead leaching from plumbing. Our city-wide citizen science water lead results contradicted official claims that there was no problem- our 90th percentile was 26.8 μg/L, which was almost double the Lead and Copper Rule action level of 15 μg/L. Back calculations of a LCR sampling pool with 50% lead pipes indicated an estimated 90th percentile lead value of 31.7 μg/L (±4.3 μg/L). Four subsequent sampling efforts were conducted to track reductions in water lead after the switch back to Lake Huron water and enhanced corrosion control. The incidence of water lead varied by service line material. Between August 2015 and November 2016, median water lead reduced from 3.0 to <1 μg/L for homes with copper service lines, 7.2-1.9 μg/L with galvanized service lines, and 9.9-2.3 μg/L with lead service lines. As of summer 2017, our 90th percentile of 7.9 μg/L no longer differed from official results, which indicated Flint's water lead levels were below the action level.
A unique microbiome establishes in the portion of the potable water distribution system within homes and other buildings (i.e., building plumbing). To examine its composition and the factors that shape it, standardized cold water plumbing rigs were deployed at the treatment plant and in the distribution system of five water utilities across the U.S. Three pipe materials (copper with lead solder, CPVC with brass fittings or copper/lead combined pipe) were compared, with 8 hour flush cycles of 10 minutes to simulate typical daily use patterns. High throughput Illumina sequencing of 16S rRNA gene amplicons was employed to profile and compare the resident bulk water bacteria and archaea. The utility, location of the pipe rig, pipe material and stagnation all had a significant influence on the plumbing microbiome composition, but the utility source water and treatment practices were dominant factors. Examination of 21 water chemistry parameters suggested that the total chlorine concentration, pH, P, SO4 2- and Mg were associated with the most of the variation in bulk water microbiome composition. Disinfectant type exerted a notably low-magnitude impact on microbiome composition. At two utilities using the same source water, slight differences in treatment approaches were associated with differences in rare taxa in samples. For genera containing opportunistic pathogens, Utility C samples (highest pH of 9–10) had the highest frequency of detection for Legionella spp. and lowest relative abundance of Mycobacterium spp. Data were examined across utilities to identify a true universal core, special core, and peripheral organisms to deepen insight into the physical and chemical factors that shape the building plumbing microbiome.
We hypothesize that the increase in reported Legionnaires' disease from June 2014 to November 2015 in Genesee County, MI (where Flint is located) was directly linked to the switch to corrosive Flint River water from noncorrosive Detroit water from April 2014 to October 2015. To address the lack of epidemiological data linking the drinking water supplies to disease incidence, we gathered physiochemical and biological water quality data from 2010 to 2016 to evaluate characteristics of the Flint River water that were potentially conducive to Legionella growth. The treated Flint River water was 8.6 times more corrosive than Detroit water in short-term testing, releasing more iron, which is a key Legionella nutrient, while also directly causing disinfectant to decay more rapidly. The Flint River water source was also 0.8-6.7 °C warmer in summer months than Detroit water and exceeded the minimum Legionella growth temperature of 20 °C more frequently (average number of days per year for Detroit was 63 versus that for the Flint River, which was 157). The corrosive water also led to 1.3-2.2 times more water main breaks in 2014-2015 compared to 2010-2013; such disruptions have been associated with outbreaks in other locales. Importantly, Legionella spp. and Legionella pneumophila decreased after switching back to Detroit water, in terms of both gene markers and culturability, when August and October 2015 were compared to November 2016.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.