This paper reports for the first time on inverse estimation of several bone properties from guided-wave measurements in human bone samples. Previously, related approaches have focused on ultrasonic estimation of a single bone property at a time. The method is based on two steps: the multi-Lamb mode response is analyzed using the singular value decomposition signal processing method recently introduced in the field, then an identification procedure is run to find thickness and anisotropic elastic properties of the considered specimen. Prior to the measurements on bone, the method is validated on cortical bone-mimicking phantoms. The repeatability and the trueness of the estimated parameters on bone-mimicking phantoms were found around a few percent. Estimation of cortical thickness on bone samples was in good agreement with cortical thickness derived from high-resolution peripheral quantitative computed tomography data analysis of the samples.
This paper is devoted to a method of extraction of guided waves phase velocities from experimental signals. Measurements are performed using an axial transmission device consisting of a linear arrangement of emitters and receivers placed on the surface of the inspected specimen. The technique takes benefit of using both multiple emitters and receivers and is validated on a reference wave guide. The guided mode phase velocities are obtained using a projection in the singular vectors basis. The singular vectors are determined by the singular values decomposition (SVD) of the response matrix between the two arrays in the frequency domain. This technique enables to recover accurately guided wave phase velocity dispersion curves. The SVD based approach was designed to overcome limitations of spatio-temporal Fourier transform for receiver array of limited spatial extent as in the case of clinical assessment of cortical bone in axial transmission.
Robust signal processing methods adapted to clinical measurements of guided modes are required to assess bone properties such as cortical thickness and porosity. Recently, an approach based on the singular value decomposition (SVD) of multidimensional signals recorded with an axial transmission array of emitters and receivers has been proposed for materials with negligible absorption, see Minonzio et al. [J. Acoust. Soc. Am. 127, 2913-2919 (2010)]. In presence of absorption, the ability to extract guided mode degrades. The objective of the present study is to extend the method to the case of absorbing media, considering attenuated plane waves (complex wavenumber). The guided mode wavenumber extraction is enhanced and the order of magnitude of the attenuation of the guided mode is estimated. Experiments have been carried out on 2 mm thick plates in the 0.2-2 MHz bandwidth. Two materials are inspected: polymethylacrylate (PMMA) (isotropic with absorption) and artificial composite bones (Sawbones, Pacific Research Laboratory Inc, Vashon, WA) which is a transverse isotropic absorbing medium. Bulk wave velocities and bulk attenuation have been evaluated from transmission measurements. These values were used to compute theoretical Lamb mode wavenumbers which are consistent with the experimental ones obtained with the SVD-based approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.