Capsular contracture remains a challenge in plastic surgery and represents one of the most common postoperative complications following alloplastic breast reconstruction. The impact of the surface structure of silicone implants on the foreign body reaction and the behaviour of connective tissue-producing cells has already been discussed. The aim of this study was to investigate different pore sizes of silicone surfaces and their influence on human fibroblasts in an in vitro model. Four different textures (no, fine, medium and coarse texture) produced with the salt-loss technique, have been assessed in an in vitro model. Human fibroblasts were seeded onto silicone sheets and evaluated after 1, 4 and 7 days microscopically, with viability assay and gene expression analysis. Comparing the growth behaviour and adhesion of the fibroblasts on the four different textures, a dense cell layer, good adhesion and bridge-building ability of the cells could be observed for the fine and medium texture. Cell number and viability of the cells were increasing during the time course of experiments on every texture. TGFß1 was lowest expressed on the fine and medium texture indicating a trend for decreased fibrotic activity. For silicone surfaces produced with the salt-loss technique, we were able to show an antifibrotic effect of smaller sized pores. These findings underline the hypothesis of a key role of the implant surface and the pore size and pore structure in preventing capsular contracture.
Background In this study, we evaluate the value of novel suture material based on monofilamentous-extruded polyfluoroethylene (PTFE) compared to polypropylene (PPL) and Fiberwire (FW). Materials and methods 60 flexor tendons were harvested from fresh cadaveric upper extremities. 4–0 sutures strands were used in the PPL, FW and PTFE group. Knotting properties and mechanical characteristics of the suture materials were evaluated. A 4-strand locked cruciate (Adelaide) or a 6-strand (M-Tang) suture technique was applied as core sutures for a tendon repair. Two-way ANOVA tests were performed with the Bonferroni correction. Results Stable knotting was achieved with 5 throws with the PPL material, 7 throws for FW and 9 throws for PTFE. In the PPL group, linear tensile strength was 45.92 ± 12.53 N, in the FW group 80.11 ± 18.34 N and in the PTFE group 76.16 ± 29.10 N. FW and PTFE are significantly stronger than PPL but show no significant difference among each other. Similar results were obtained in the subgroup comparisons for different repair techniques. The Adelaide and the M-Tang knotting technique showed no significant difference. Conclusion Fiberwire showed superior handling and knotting properties in comparison to PTFE. However, PTFE allows easier approximation of the stumps. In both, M-Tang and Adelaide repairs, PTFE was equal to FW in terms of repair strength. Both PTFE and FW provide for a robust tendon repair so that early active motion regimens for rehabilitation can be applied.
Peri-prosthetic breast infections pose a risk of severe complications after breast implant surgery. The need to remove the breast implant, control the infection and perform additional surgical procedures are the consequences. Reimplantation of an alloplastic implant is only appropriate after an infection-free interval. In this retrospective cohort study, we investigated the effectiveness of negative pressure wound treatment with instillation and dwell time (NPWTi-d) on peri-prosthetic breast infections in combination with implant removal and antibiotic therapy. Twelve patients treated with NPWTi-d due to breast implant infection were included in the study. The bacterial burden was analyzed using wound swabs before and after NPWTi-d. Additionally, laboratory values were determined before NPWTi-d and immediately before wound closure. A total of 13 peri-prosthetic breast infections in 12 patients were treated using implant removal and NPWTi-d. In 76.9% (n = 10) of the cases, the patients had undergone alloplastic breast reconstruction following cancer-related mastectomy, whereas 23.1% (n = 3) of the patients had undergone breast augmentation for cosmetic reasons. The bacterial burden in the breast pocket decreased statistically significant after implant removal and NPWTi-d. No shift from Gram-positive to Gram-negative bacteria was observed. Inflammatory markers rapidly decreased following treatment. NPWTi-d had a positive impact on the healing process after peri-prosthetic breast infections, leading to a decrease in bacterial burden within the wounds and contributing to uneventful healing. Therefore, secondary reimplantation of breast prostheses might be positively influenced when compared to conventional implant removal and simple secondary closure. Further studies are required to conclusively establish the beneficial long-term effects of using NPWTi-d for the treatment of peri-prosthetic breast infections.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.