The good specificity, sensitivity, precision, subtype performance and clinical agreement with other assays demonstrated by Aptima combined with the complete automation provided by the Panther platform makes Aptima a good candidate for both VL monitoring and diagnosis of HIV-1.
BackgroundQuantitation of HIV-RNA is critically important for diagnosis, prognosis, treatment, monitoring and assessment of infectivity in HIV-1 infection. The objective of this study was to assess performance characteristics of the Aptima HIV-1 Quant Dx assay (Aptima), a new transcription mediated amplification (TMA), fully integrated and automated assay from Hologic Inc., San Diego, CA, USA.The analytical sensitivity, analytical specificity, precision and detection of HIV-1 subtypes were tested based on commercially available international standards or panels. A selected group of 244 anti-HIV-1 (+) plasma samples was used for comparison with Roche COBAS Ampliprep/COBAS TaqMan HIV- 1 test v2.0 (Roche CAP/CTM), (Roche Molecular Systems, Pleasanton, CA).ResultsThe 50 and 95 % limit of detection were estimated at 4.9 (95 % CI 3.9–5.7) and 17.6 (15.2–21.2) IU/mL respectively. The specificity was found 99.83 (99.06–99.97) %. The standard deviations and coefficient of variations for panels with 50 and 100 copies/mL (1.7 and 2 log copies/mL) were 0.14 log copies/mL (8.67 %CV) and 0.18 log copies/mL (9.91 %CV) respectively. The detection rate for Aptima and Roche assays was 220/244 (90.2 %) and 217/244 (88.9 %) respectively.ConclusionThe Aptima assay is a sensitive, specific, precise and accurate test for measuring HIV-1 viral loads and for the detection of HIV-1 infections.
Quantification of HIV-1 RNA is essential for clinical management of HIV patients. The limited throughput and significant hands-on time required by most HIV Viral load (VL) tests makes it challenging for laboratories with high test volume, to turn around patient results quickly. The Hologic Aptima HIV-1 Quant Dx Assay (Aptima), has the potential to alleviate this burden as it is high throughput and fully automated. This assay is validated for both plasma and dried blood spots (DBS), which are commonly used in resource limited settings. The objective of this study was to compare the performance of Aptima to Abbott RealTime HIV-1 Assay (Abbott RT), which was used as reference. This was a cross-sectional prospective study where HIV VL in finger stick (FS) DBS, venous blood (VB) DBS and plasma, collected from 258 consenting adults visiting 5 medical facilities in Kenya, Africa were tested in Aptima. The results were compared to plasma VL in Abbott RT at the medical decision point (MDP) of 1000 copies/mL and across Aptima assay range. The total agreement at MDP between plasma HIV VL in Abbott RT and plasma, FS and VB DBS tested in Aptima were 97.7%, 92.2% and 95.3% respectively with kappa statistic of 0.95, 0.84 and 0.90. The positive and negative agreement for all 3 sample types were >92%. Regression analysis between VL in Abbott RT plasma and various sample types tested in Aptima had a Pearson’s correlation coefficient ≥0.91 with systematic bias of < 0.20 log copies/mL on Bland-Altman analysis. The high level of agreement in Aptima HIV VL results for all 3 sample types with Abbott RT plasma VL along with the high throughput, complete automation, and ease of use of the Panther platform makes Aptima a good option for HIV VL monitoring for busy laboratories with high volume of testing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.