Endoluminal devices such as metallic flow diversion (FD) and aneurysm bridging (AB) stents are used for treatment of intracranial aneurysms. Treatments are associated with thrombogenic events mandating the use of dual antiplatelet therapy in all cases. In the current in vitro study, we utilize a slow binding fluorogenic thrombin specific substrate to measure the thrombin generation potential of six devices: four FD devices (Pipeline™ Flex embolization device, Pipeline™ Flex embolization device with Shield Technology™, SILK+, FRED™) and two AB devices (Solitaire™ AB, LEO+). We show that the Pipeline™ Flex embolization device with Shield Technology™ has significantly lower peak thrombin and takes significantly longer time to achieve peak thrombin (time to peak) compared to the other three FD devices (p < 0.05), with statistically similar results to the less thrombogenic AB devices. We conclude that surface modification of endoluminal stents could be an effective method to mitigate thrombogenic complications.
BackgroundFlow diverters offer a promising treatment for cerebral aneurysms. However, they have associated thromboembolic risks, mandating chronic dual antiplatelet therapy (DAPT). Shield Technology is a phosphorylcholine surface modification of the Pipeline Embolization Device (PED) flow diverter, which has shown significant reductions in material thrombogenicity in vitro.ObjectiveTo compare the thrombogenicity of PED, PED with Shield Technology (PED+Shield), and the Flow-Redirection Endoluminal Device (FRED)—with and without single antiplatelet therapy and DAPT—under physiological flow.MethodsAn established non-human primate ex vivo arteriovenous shunt model of stent thrombosis was used. PED, PED+Shield, and FRED were tested without antiplatelet therapy, with acetylsalicylic acid (ASA) monotherapy, and with DAPT. Radiolabeled platelet deposition was quantified over 1 hour for each device and total fibrin deposition was also quantified.ResultsCumulative statistical analysis showed significantly lower platelet deposition on PED compared with FRED. The same statistical model showed significant decreases in platelet deposition when ASA, clopidogrel, or Shield Technology was used. Direct comparisons of device performances within antiplatelet conditions showed consistent significant decreases in platelet accumulation on PED+Shield relative to FRED. PED+Shield showed significant reductions in platelet deposition compared with unmodified PED without antiplatelet therapy and with DAPT. PED accumulated minimal fibrin with and without Shield Technology.ConclusionsIn this preclinical model, we have shown that the Shield Technology phosphorylcholine modification reduces the platelet-specific thrombogenicity of a flow diverter under physiologically relevant flow with and without DAPT. We have further identified increased fibrin-driven thrombogenicity associated with FRED relative to PED.
Background: Surgical reconstruction of congenital heart defects is often limited by the nonresorbable material used to approximate normal anatomy. In contrast, biologic scaffold materials composed of resorbable non-cross-linked extracellular matrix (ECM) have been used for tissue reconstruction of multiple organs and are replaced by host tissue. Preparation of whole organ ECM by decellularization through vascular perfusion can maintain much of the native three-dimensional (3D) structure, strength, and tissue-specific composition. A 3D cardiac ECM (C-ECM) biologic scaffold material would logically have structural and functional advantages over materials such as Dacron™ for myocardial repair, but the in vivo remodeling characteristics of C-ECM have not been investigated to date. Methods and Results: A porcine C-ECM patch or Dacron patch was used to reconstruct a full-thickness right ventricular outflow tract (RVOT) defect in a rat model with end points of structural remodeling function at 16 weeks. The Dacron patch was encapsulated by dense fibrous tissue and showed little cellular infiltration. Echocardiographic analysis showed that the right ventricle of the hearts patched with Dacron were dilated at 16 weeks compared to presurgery baseline values. The C-ECM patch remodeled into dense, cellular connective tissue with scattered small islands of cardiomyocytes. The hearts patched with C-ECM showed no difference in the size or function of the ventricles as compared to baseline values at both 4 and 16 weeks. Conclusions: The C-ECM patch was associated with better functional and histomorphological outcomes compared to the Dacron patch in this rat model of RVOT reconstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.