This paper presents the analysis and assessment of water losses in water distribution systems of three water supply companies operating water supply networks in the area of effect of underground mining. The analysis of water losses was conducted based on numerous indices allowing for obtaining objective information on the condition of the water supply system. The method of the analysis of percentage water loss index was extended by the methods of determination of losses according to the International Water Association. The results of the analysis lead to the conclusion that with regular actions, the companies have reduced water losses in recent years to a level considered to be good compared to national data and average compared to international standards. The value of the failure intensity index for all companies in 2011 was over 1.0 while currently it is about 0.5. The decrease in Non-Revenue Water basic loss index (NRWB) from more than 20% for all analysed companies in 2008 to a few percent in 2017 and the decrease in Infrastructure Leakage Index (ILI) for companies A and C to less than 2.0 are evidence of the good condition of the network. This is also confirmed by the unit water loss index per capita, with its value in 2017 being 9.1 dm3/(inhabitant day) for company A, 11 dm3/(inhabitant·day) for B and 7.4 dm3/(inhabitant·day) for C. The several years of analysis and evaluation of numerous indices of water loss presented in the paper reveals the effectiveness of the adopted strategies of reducing leakages in the distribution system. It should be emphasized that the analysed companies have been involved in comprehensive initiatives aimed at reducing water leakages, resulting in a substantial reduction in water losses. GIS monitoring systems and databases are particularly helpful in reducing water losses. The basis of the activities is monitoring of flow and pressure in water supply networks and active leakage control. Network zoning with simultaneous observation of minimum night-time flows allows for preliminary location of the failure. Equipping companies with special leakage detection devices such as geophones, stethophones or correlators enables quick detection of leakages. The next step is to replace water meters with more and more accurate ones and to implement radio reading of water meters. All analysed companies perform systematic replacement of old steel and cast iron pipes which cause a large number of leakages that are often difficult to identify, thus leading to water losses.
Progressive economic development as well as urbanisation influence the characteristics of the stormwater runoff. Progressive sealing of drainage basin surface prompts the decrease of rainwater infiltration, thus increasing the runoff intensity. This results in an increase of flood risk. Thus, in urban areas the sustainable urban drainage systems (SUDS) are used in addition to the traditional sewer systems. The examples of SUDS strategy are, inter alia, the roofs covered with vegetation (the green roofs). The paper presents the results of research of retention capacities of 4 diverse green roof models with following growing media: (1) the typical green roof substrate without any additions, (2) the substrate with addition of about 1 % by weight of hydrogel (the cross-linked potassium polyacrylate), (3) the substrate with addition of about 0.25 % by weight of hydrogel, (4) the substrate with addition of expanded clay and perlite. The models did not have the vegetation layers in order to explore only the retention capacities of drainage layers and substrates. The aim of the first part of research was to investigate the retention capacities of green roof models after 1, 2, 6, 8 and 10 antecedent dry days. In the case of 1 and 2 antecedent dry days the best medium retention capacity had green roof model 2 (with substrate with addition of 1 % by weight of hydrogel), and the weakest medium retention capacity had green roof model 1 (without any additions). In the cases of precipitations which occurred after 6 as well as 8 and 10 antecedent dry days the best retention capacity had green roof model 3 (with addition of about 0.25 % by weight of hydrogel). The weakest retention capacity had in these cases green roof model 4 (with addition of expanded clay and perlite). The aim of the second part of research described in the paper was to investigate the retention capacities of green roof models during precipitations that occurred after long antecedent dry periods of time (34, 59 and 106 antecedent dry days). The substrates and drainage layers were air-dry directly before precipitations. The best retention capacity had in this case green roof model 3 (with the substrate with addition of about 0.25 % by weight of hydrogel). The second largest retention capacity had model 2 (with the substrate with addition of about 1 % by weight of hydrogel). The definitely weakest retention capacity had model 4 containing the substrate with addition of expanded clay and perlite. The results may indicate that the efficacy of hydrogel decreased over time probably due to its decay under the influence of solar radiation.
The purpose of this article is to analyze and compare the benefits of and barriers to the implementation of Environmental Management Systems (EMS)—International Standard ISO 14001 and Eco-Management and Audit Scheme (EMAS)—by organizations. This paper attempts to answer the following research questions: 1. Does the implementation of either ISO 14001 or EMAS bring the same benefits and barriers to organizations? 2. Does the system functioning duration in the company influence internal and external benefits resulting from EMS implementation? 3. Are economic aspects of EMS adoption as important for entrepreneurs as the ecological aspects? This topic is important due to the large disproportions appearing in recent years between the number of companies registered in ISO 14001 and in EMAS, and due to relatively frequent cases of non-renewal of EMAS certifications in recent years. It is crucial because each EMS certified institution has implemented procedures which contribute to better protection of the natural environment. The study was conducted in the form of a survey; questions and answers were specified based on the literature review and the authors’ research. Results indicate that the knowledge-based and organizational problems, as well as the time invested in preparing the documentation, are much more significant than financial problems associated with EMS implementation. Even organizations that previously introduced ISO 14001 still have difficulties with EMAS implementation. The perception of benefits resulting from EMS introduction is related to the system functioning duration in the company. The analysis shows that it is necessary to strengthen economic incentives in order to enable the widest possible dissemination of EMS among companies. Research results can contribute to further simplification and increases in EMS implementation, which may lead to more sustainable development and climate change mitigation, inter alia, due to the improvement in energy efficiency, increased use of renewable energy, and reduction of greenhouse gas emissions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.