These results demonstrate that although trans-apical trans-catheter aortic valve implantation is a complex surgical technique, the learning curve can be minimised by appropriate training programmes. Very high logistic EuroSCOREs predict inferior survival and make it likely that in this subgroup of patients there may be some who, despite having had a successful trans-catheter aortic valve implantation procedure, do not benefit in the midterm.
Although the incidence of technical intra procedural complications has trended downward, reflecting the learning curve for TA-AVI, 30-day mortality was unchanged, likely due to patient co-morbidities not captured by preoperative risk variables.
Background We retrospectively evaluated vascular complications and wound infections after surgical or percutaneous transfemoral removal of temporary extracorporeal life support systems (ECLSs).
Methods A total of 83 patients were weaned from ECLS between August 2015 and September 2020. We analyzed for a composite endpoint of vascular complications and wound infections requiring negative-pressure wound therapy. Patients were divided into two groups: percutaneous group using the MANTA vascular occlusion system (VCD; Teleflex, Morrisville, North Carolina, United States) (n = 23) and surgical group (n = 60).
Results The median age in the entire cohort was 67 years. Vascular complications were seen in 20% (n = 12) in the surgical group and in 13% (n = 3) in the percutaneous group (p = 0.72). A total of 32% (n = 19) in the surgical group and 9% (n = 2) in the percutaneous group (p = 0.031) had wound infections. A composite endpoint of vascular complications and wound infections showed significantly more complications in the surgical group (52%, n = 31) as compared with the percutaneous group (22%, n = 5) (p = 0.020). The median duration in the intensive care unit was 13 days for the surgical group and 12 days for the percutaneous group without any significant difference in both groups (p = 0.93).
Conclusions Using the MANTA VCD for percutaneous removal of ECLS cannulas after weaning from ECLS is safe and reproducible. A composite endpoint of vascular complications and wound infections was significantly lower in the percutaneous removal group as compared with the surgical group.
These results demonstrate that in elderly patients with severe co-morbidities, TA aortic valve implantation results in excellent mid-term results. Causes of death during the mid-term follow-up are mainly non-cardiac and related to co-morbidities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.