Introduction
Amyloid-β (Aβ) clearance is important for damage prevention in Alzheimer's disease. We investigated the utility of Aβ clearance proteins as biomarkers for mild cognitive impairment (MCI).
Methods
Serum apolipoprotein (apo) A-I, compliment protein C3 (C3), transthyretin, and cholesterol levels were measured in 273 subjects, and we analyzed the relationship between these levels and brain atrophy and cerebral blood flow in 63 clinically diagnosed mild cognitive impairment, Alzheimer's disease, and nondemented disease control subjects.
Results
ApoA-I and transthyretin levels and the active form of C3:native form of C3 ratio achieved an area under the curve of 0.89 (sensitivity: 83%, specificity: 90%) for detecting late mild cognitive impairment. Atrophy was associated with decreased apoA-I and high-density lipoprotein levels. Subjects with reduced cerebral blood flow had lower levels of native form of C3, apoA-I, high-density lipoprotein, and total cholesterol. Low native form of C3 and high active form of C3 levels were found in the hippocampi of patients with Alzheimer's disease.
Discussion
Aβ clearance proteins in the serum are potential biomarkers for mild cognitive impairment evaluation.
A room-temperature pulsed operation was demonstrated using lateral current injection-type lasers composed of a 400-nm-thick GaInAsP core layer with compressively strained 5 quantum wells. A threshold current of 105 mA and corresponding density of 1.3 kA/cm 2 (260 A/cm 2 per well) were obtained with the stripe width of 5.4 µm and the cavity length of 1.47 mm. A fundamental transverse mode operation was obtained with the narrower stripe device of 2.0 µm and the cavity length of 805 µm, while the threshold current and corresponding density were 49 mA and 3.0 kA/cm 2 , respectively.
We fabricated a novel lateral-current-injection-type distributed feedback (DFB) laser with amorphous-Si (a-Si) surface grating as a step to realize membrane lasers. This laser consists of a thin GaInAsP core layer grown on a semi-insulating InP substrate and a 30-nm-thick a-Si surface layer for DFB grating. Under a room-temperature continuous-wave condition, a low threshold current of 7.0 mA and high efficiency of 43% from the front facet were obtained for a 2.0-μm stripe width and 300-μm cavity length. A small-signal modulation bandwidth of 4.8 GHz was obtained at a bias current of 30 mA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.