The aim of this study was to fabricate novel self-supporting tacrolimus suppositories using semisolid extrusion 3-dimensional printing (3DP) and to investigate their efficacy in an experimental model of inflammatory bowel disease. Blends of Gelucire 44/14 and coconut oil were employed as lipid excipients to obtain suppository formulations with self-emulsifying properties, which were then tested in a TNBS (2,4,6-trinitrobenzenesulfonic acid) induced rat colitis model. Disease activity was monitored using PET/CT medical imaging; maximum standardized uptake values (SUVmax), a measure of tissue radiotracer accumulation rate, together with body weight changes and histological assessments, were used as inflammatory indices to monitor treatment efficacy. Following tacrolimus treatment, a significant reduction in SUVmax was observed on days 7 and 10 in the rat colon sections compared to non-treated animals. Histological analysis using Nancy index confirmed disease remission. Moreover, statistical analysis showed a positive correlation (R2 = 71.48%) between SUVmax values and weight changes over time. Overall, this study demonstrates the effectiveness of 3D printed tacrolimus suppositories to ameliorate colitis and highlights the utility of non-invasive PET/CT imaging to evaluate new therapies in the preclinical area.
AIMTo evaluate factors that influence the diagnostic accuracy of endoscopic ultrasound (EUS)-guided tissue acquisition for lymph node enlargement in the absence of an on-site pathologist.METHODSA retrospective analysis of patients who underwent EUS-guided tissue acquisition for the pathological diagnosis of lymph node enlargement between April 2012 and June 2015 is reported. Tissue acquisition was performed with both cytology and biopsy needles of different calibers. The variables evaluated were lymph node location and size, number of passes and type of needle used. Final diagnosis was based on surgical histopathology or, in non-operated cases, on EUS-guided tissue acquisition and imaging assessment with a minimum clinical follow-up of 6 mo.RESULTSDuring the study period, 168 lymph nodes with a median size of 20.3 mm (range 12.5-27) were sampled from 152 patients. Ninety lymph nodes (53.6%) were located at mediastinum, and 105 (62.5%) were acquired with biopsy needles. The final diagnosis was benign/reactive origin in 87 cases (51.8%), malignant in 65 cases (38.7%), and lymphoma in 16 cases (9.5%). The sensitivity, specificity, positive predictive value and negative predictive value for the detection of malignancy were 74.1%, 100%, 100% and 80.6%, respectively. The overall accuracy was 87.5% (95%CI: 81.7-91.7). No variables were independently associated with a correct final diagnosis according to the multivariate analysis.CONCLUSIONEUS-guided tissue acquisition is a highly accurate technique for assessing lymph node enlargement. None of the variables evaluated were associated with diagnostic accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.