Moderate evidence exists that shorter resin tag penetration produces less change in enamel colour following clean-up and polishing. Self-etch primers produce less resin penetration and these systems may produce less iatrogenic colour change in enamel following orthodontic treatment.
Soft tissue changes following maxillary posterior teeth intrusion with zygomatic miniplates and premolar extractions appear to be stable 4 years after treatment.
Background
To evaluate the accuracy of three different 3D digital model registration software packages for linear tooth movement measurements, with reference to a 3D digital virtual setup (DS).
Methods
Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital Setups were generated from pre-treatment scans using OrthoAnalyzer software. Both the pretreatment digital scans (T1) and Digital Setups (T2) were converted to STL files to be imported to the three studied software packages: Geomagic, OrthoAnalyzer and Compare. Linear changes in tooth positions were calculated for all the registered pairs.
Results
The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the Digital Setups. Continuous data was expressed as mean and standard deviation. Intraclass Correlation Coefficients for agreements between Digital Simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intraclass Correlation Coefficients. Significance of the obtained results was expressed at p ≤ 0.01. Geomagic software showed agreements > 0.90 for maxillary linear tooth movements and between 0.75 and 0.90 for mandibular measurements. OrthoAnalyzer software showed agreements between 0.50 and < 0.75 for maxillary and mandibular measurements. Compare software showed agreements > 0.90 for maxillary and mandibular linear tooth movements, indicating the best consistency.
Conclusions
Compare and Geomagic software packages consistently showed maximum accuracy in measuring the amount of tooth movement in the maxillary arch compared to the reference standard. Compare software showed the highest agreements in the mandibular arch. None of the three studied software packages showed poor agreement with the Digital Setup across all tooth movement measurements. Buccolingual tooth movements showed the highest agreements amongst linear measurements.
Background
To investigate the accuracy of three different 3D digital model registration software for tip, torque and rotation measurements, with reference to a 3D digital virtual setup. Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital setups were generated from pre-treatment scans using a tooth movement software. Both the pretreatment digital scans (T1) and digital setups (T2) were converted to STL files to be exported to the 3 studied software that employed: (1) Semiautomatic best fit registration (S-BF), (2) Interactive surface-based registration (I-SB), and (3) Automatic best fit registration (A-BF) respectively. Changes in tip, torque and rotation were calculated for all the registered pairs.
Results
The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the digital setups. Continuous data was expressed as mean and standard deviation. Intra Class Correlation Coefficient for agreement between digital simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intra Class Correlation Coefficient. Significance of the obtained results was expressed at p ≤ 0.01. Semiautomatic best fit registration software showed excellent agreement (> 0.90) for all tooth movements, except for good agreement for torque (0.808). Interactive surface-based registration software showed moderate agreement for all measurements (0.50 and < 0.75), except for good agreement for rotation (0.783). Automatic best fit registration software demonstrated excellent agreement (> 0.90) for rotation, good agreement for tip (0.890) and moderate agreement for torque (0.740).
Conclusions
Overall, semiautomatic best fit registration software consistently showed excellent agreement in superimpositions compared to other software types. Automatic best fit registration software consistently demonstrated better agreement for mandibular superimpositions, compared to others. Accuracy of digital model superimpositions for tooth movements studied in superimposition studies, can be attributed to the algorithm employed for quantification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.